A New Optical Method for Suppressing Radial Magnetic Error in a Depolarized Interference Fiber Optic Gyroscope.

Sci Rep

State Key Laboratory of Modern Optical Instrumentation, Zhejiang University, Hangzhou, 310027, Zhejiang, China.

Published: January 2018

Based on the theory of the radial magnetic error (RME) in depolarized interference fiber optic gyroscopes (D-IFOGs) under magnetic field, a new optical method is proposed to decrease the RME by adding a suppressing section fiber (SSF) in D-IFOGs. A related theoretical model is established, and the solutions of the parameters of the SSF are obtained with numerical calculations. Then the results of the suppressed RME are simulated. An experimental system is set up to verify the theory and simulation, and the experimental results prove that the RME can be suppressed effectively with a SSF added in the D-IFOG. The magnitude of the RME can be reduced to one-tenth of the original.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5792582PMC
http://dx.doi.org/10.1038/s41598-018-20487-xDOI Listing

Publication Analysis

Top Keywords

optical method
8
radial magnetic
8
magnetic error
8
depolarized interference
8
interference fiber
8
fiber optic
8
rme
5
method suppressing
4
suppressing radial
4
error depolarized
4

Similar Publications

Deep Equilibrium Unfolding Learning for Noise Estimation and Removal in Optical Molecular Imaging.

Comput Med Imaging Graph

January 2025

CAS Key Laboratory of Molecular Imaging, Institute of Automation, Chinese Academy of Sciences, Beijing 100190, China; School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing 100049, China; National Key Laboratory of Kidney Diseases, Beijing 100853, China. Electronic address:

In clinical optical molecular imaging, the need for real-time high frame rates and low excitation doses to ensure patient safety inherently increases susceptibility to detection noise. Faced with the challenge of image degradation caused by severe noise, image denoising is essential for mitigating the trade-off between acquisition cost and image quality. However, prevailing deep learning methods exhibit uncontrollable and suboptimal performance with limited interpretability, primarily due to neglecting underlying physical model and frequency information.

View Article and Find Full Text PDF

Digital Frequency Customized Relieving Sound for Chronic Subjective Tinnitus Management: Prospective Controlled Study.

J Med Internet Res

January 2025

ENT Institute and Department of Otorhinolaryngology, Eye & ENT Hospital, Fudan University, Shanghai, China.

Background: Tinnitus is a major health issue, but currently no tinnitus elimination treatments exist for chronic subjective tinnitus. Acoustic therapy, especially personalized acoustic therapy, plays an increasingly important role in tinnitus treatment. With the application of smartphones, personalized acoustic stimulation combined with smartphone apps will be more conducive to the individualized treatment and management of patients with tinnitus.

View Article and Find Full Text PDF

Background And Objectives: Despite the absence of acute lesion activity in multiple sclerosis (MS), chronic neurodegeneration continues to progress, and a potential underlying mechanism could be the kynurenine pathway (KP). Prolonged activation of the KP from chronic inflammation is known to exacerbate the progression of neurodegenerative diseases through the production of neurotoxic metabolites. Among the 8 KP metabolites, six of them, namely kynurenine (KYN), 3-hydroxylkynurenine (3HK), anthranilic acid (AA), kynurenic acid (KYNA), and quinolinic acid (QUIN), have been associated with neurodegeneration.

View Article and Find Full Text PDF

We have successfully prepared a significant number of nanowires from non-toxic silicon sources. Compared to the SiO silicon source used in most other articles, our preparation method is much safer. It provides a simple and harmless new preparation method for the preparation of silicon nanowires.

View Article and Find Full Text PDF

Objectives: The coronary heart disease (CHD) can influence the development of several diseases. The presence of CHD is correlated to a higher incidence of concurrent diabetic retinopathy (DR) in previous study. Herein, we aim to analyze the relationship between the CHD severity and following DR with different severity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!