On the Design of an Efficient Cardiac Health Monitoring System Through Combined Analysis of ECG and SCG Signals.

Sensors (Basel)

Graduate Institute of Medical Mechatronics, Center for Biomedical Engineering, Chang Gung University, Guishan 33302, Taiwan.

Published: January 2018

Cardiovascular disease (CVD) is a major public concern and socioeconomic problem across the globe. The popular high-end cardiac health monitoring systems such as magnetic resonance imaging (MRI), computerized tomography scan (CT scan), and echocardiography (Echo) are highly expensive and do not support long-term continuous monitoring of patients without disrupting their activities of daily living (ADL). In this paper, the continuous and non-invasive cardiac health monitoring using unobtrusive sensors is explored aiming to provide a feasible and low-cost alternative to foresee possible cardiac anomalies in an early stage. It is learned that cardiac health monitoring based on sole usage of electrocardiogram (ECG) signals may not provide powerful insights as ECG provides shallow information on various cardiac activities in the form of electrical impulses only. Hence, a novel low-cost, non-invasive seismocardiogram (SCG) signal along with ECG signals are jointly investigated for the robust cardiac health monitoring. For this purpose, the in-laboratory data collection model is designed for simultaneous acquisition of ECG and SCG signals followed by mechanisms for the automatic delineation of relevant feature points in acquired ECG and SCG signals. In addition, separate feature points based novel approach is adopted to distinguish between normal and abnormal morphology in each ECG and SCG cardiac cycle. Finally, a combined analysis of ECG and SCG is carried out by designing a Naïve Bayes conditional probability model. Experiments on Institutional Review Board (IRB) approved licensed ECG/SCG signals acquired from real subjects containing 12,000 cardiac cycles show that the proposed feature point delineation mechanisms and abnormal morphology detection methods consistently perform well and give promising results. In addition, experimental results show that the combined analysis of ECG and SCG signals provide more reliable cardiac health monitoring compared to the standalone use of ECG and SCG.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5856087PMC
http://dx.doi.org/10.3390/s18020379DOI Listing

Publication Analysis

Top Keywords

ecg scg
28
cardiac health
24
health monitoring
24
scg signals
16
combined analysis
12
analysis ecg
12
cardiac
10
ecg
10
scg
8
ecg signals
8

Similar Publications

There is an ongoing search for a reliable and continuous method of noninvasive blood pressure (BP) tracking. In this study, we investigate the feasibility of utilizing seismocardiogram (SCG) signals, i.e.

View Article and Find Full Text PDF
Article Synopsis
  • The study aims to evaluate the effectiveness of seismocardiogram (SCG) and gyrocardiogram (GCG) in differentiating aortic stenosis (AS) patients from healthy individuals, discovering the best sensor placement for accurate classification.
  • SCG and GCG data were collected from 15 participants and analyzed using both machine learning and deep learning techniques, yielding the highest accuracy from the Support Vector Machine (SVM) at specific heart locations.
  • By combining SCG and GCG signals, accuracy improved significantly, reaching up to 97.2% with a single sensor, demonstrating a reliable method for classifying AS patients.
View Article and Find Full Text PDF

Cardiovascular disease (CVD) is the leading cause of death worldwide. Coronary artery disease (CAD), a prevalent form of CVD, is typically assessed using catheter coronary angiography (CCA), an invasive, costly procedure with associated risks. While cardiac computed tomography angiography (CTA) presents a less invasive alternative, it suffers from limited temporal resolution, often resulting in motion artifacts that degrade diagnostic quality.

View Article and Find Full Text PDF
Article Synopsis
  • Wearable sensors like Seismocardiography (SCG) offer non-invasive cardiac health monitoring, but challenges from motion artefacts, primarily caused by walking, limit their effectiveness.
  • The Adaptive Bidirectional Filtering (ABF) technique improves SCG signal quality by using advanced noise-cancellation and a unique filtering process that distinguishes between actual heart signals and motion noise.
  • Empirical tests show ABF achieves high accuracy in heart rate estimation (r-squared value of 0.95 at -20 dB SNR) and effectively reduces motion artefacts without needing ECG inputs, making it suitable for use in noisy settings.
View Article and Find Full Text PDF

Goal: We present a thin, soft, and chest conformable bimodal sensor, known as the chest e-tattoo, coupled with an advanced signal processing framework to accurately identify various cardiac events, and thereby extract cardiac time intervals even during body motion.

Methods: We built a wireless electronic tattoo that features synchronous electrocardiography (ECG) and seismocardiography (SCG). The SCG measures chest vibrations due to heartbeat, providing information on cardiovascular health that is complementary to the ECG.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!