A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pseudo-Infected Red Blood Cell Beads as Positive Control for Cell Microarray Chip-Based Detection of Plasmodium-Infected RBCs. | LitMetric

AI Article Synopsis

  • The cell microarray chip, designed to detect malaria-infected red blood cells, contains 20,944 microchambers for analyzing about 130 RBCs each.
  • iRBCs are stained and identified using fluorescence, allowing for the determination of malaria infection rates.
  • The introduction of “pseudo-iRBC beads” as a positive control helps ensure accurate diagnostics in remote areas by mimicking infected cells and confirming the chip’s effectiveness.

Article Abstract

The cell microarray chip is a polystyrene plate with 20,944 microchambers, and it is used to detect red blood cells (RBCs) infected with the causative agent of malaria, Plasmodium. Plasmodium-infected red blood cells (iRBCs) stained with a nuclear staining dye (SYTO 21) form a monolayer on the bottom of the microchambers, and about 130 RBCs are accommodated in each such microchamber of the chip. The iRBCs in the RBC monolayer (containing 2.7 million RBCs) can be identified using a fluorescence detector, and the infection rate can be calculated by counting the number of fluorescent-positive RBCs. This diagnostic device is highly sensitive and hence advantageous for early diagnosis of malaria infections in endemic areas. However, a standard positive control for Plasmodium-infected RBCs is required to ensure that the reagents and detectors of these cell microarray chips are working efficiently in remote endemic areas. Here, we introduce "pseudo-iRBC beads," which consist of a mixture of DEA beads mimicking RBCs and DEA beads coated with nucleic acids mimicking nuclei of the parasite. These beads can be stained with SYTO 21, applied onto the cell microarray chip to form a monolayer, and detected using the fluorescence detector in the same way as iRBCs. Therefore, the introduction of pseudo-iRBC beads as a positive control ensures unbiased malaria diagnoses with the cell microarray chip device in remote endemic areas.

Download full-text PDF

Source
http://dx.doi.org/10.1645/17-144DOI Listing

Publication Analysis

Top Keywords

cell microarray
20
red blood
12
positive control
12
microarray chip
12
endemic areas
12
beads positive
8
plasmodium-infected rbcs
8
blood cells
8
form monolayer
8
fluorescence detector
8