Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To understand the quality of blood smears for detection in Changzhou City, so as to provide the technical support for malaria surveillance in the post-elimination period.
Methods: The blood smears of fever patients from each cities (districts) in Changzhou City in 2014, including more than 3% of the negatives and all the positives, were selected. The quality of the blood smear making, dyeing, cleanliness and results were reviewed by the experts from the municipal malaria microscopy station, and the data were analyzed statistically.
Results: Totally 996 negative blood smears were reviewed in 2014, with a review rate of 4.52%. The qualified rates of blood smear making, dyeing and cleanliness were 92.87%, 93.27% and 94.48%, respectively. A total of 34 positive blood smears were reviewed, and there were no false detections and leak detections. The qualified rates of blood smear making and dyeing were more than 90% in all the seven cities (districts). As for qualified rate of cleanliness, except the rate in Qishuyan District (81.36%), those in the other six cities (districts) were all above 90%. The qualified rates of blood smear making, dyeing and cleanliness were all more than 90% in first-class, second-class and third-class hospitals. The major quality defects of the blood smears were sediment, abnormal making and thick membrane shedding, and the proportions were 25.91%, 21.76% and 19.17%, respectively.
Conclusions: The quality of blood smears for detection in Changzhou City is satisfying. In the future, the training and supervision still should be strengthened to guarantee the capacity of microscopic examinations for detection in the surveillance of post-elimination period.