Rationale And Objectives: To evaluate two- and three-dimensional (2D and 3D) image quality of sub-milliSievert (mSv) computed tomography (CT) colonography utilizing a third-generation dual source CT scanner featuring a tin filter.

Methods: We retrospectively evaluated 26 consecutive patients who underwent third-generation dual source CT colonography, nine with the standard-dose clinical-scan protocol (SDP) and 17 with a low-dose protocol (LDP) featuring a tin filter. Radiation dose was evaluated by volume computed tomography dose index (CTDI), dose length product (DLP), effective dose (E), and size-specific dose estimate. Objective image quality was evaluated utilizing signal-to-noise ratio (SNR) derived from standardized placed regions of interest on the transverse 2D images and the ratio of SNR/CTDI (normalized SNR). Two radiologists in consensus assessed subjective image quality of the virtual 3D images.

Results: There were no significant differences in subjective image quality (P = .661). All examinations were rated "excellent" or "good" for diagnostic confidence. The mean total for DLP/E was 143.4 ± 29.8 mGy/3.00 ± 0.40 mSv in the SDP and therefore significantly higher than in the LDP with 36.9 ± 8.7 mGy/0.75 ± 0.16 mSv (P < .001). The SNR was 8.9 ± 2.1 in the SDP and 4.9 ± 0.8 in the LDP.

Conclusions: Third-generation dual source CT featuring a tin filter enables consistent sub-mSv colonography without substantially impairing image quality.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.acra.2017.12.014DOI Listing

Publication Analysis

Top Keywords

image quality
20
computed tomography
12
third-generation dual
12
dual source
12
featuring tin
12
tomography colonography
8
source scanner
8
scanner featuring
8
subjective image
8
image
5

Similar Publications

Optical metasurfaces, arrays of nanostructures engineered to manipulate light, have emerged as a transformative technology in both research and industry due to their compact design and exceptional light control capabilities. Their strong light-matter interactions enable precise wavefront modulation, polarization control, and significant near-field enhancements. These unique properties have recently driven their application in biomedical fields.

View Article and Find Full Text PDF

Injectable DAT-ALG Hydrogel Mitigates Senescence of Loaded DPMSCs and Boosts Healing of Perianal Fistulas in Crohn's Disease.

ACS Biomater Sci Eng

January 2025

Department of Gastrointestinal Surgery, Affiliated Hospital of Nantong University, Medical School of Nantong University, Nantong 226001, China.

Perianal fistulas (PAFs) are a severe complication of Crohn's disease that significantly impact patient prognosis and quality of life. While stem-cell-based strategies have been widely applied for PAF treatment, their efficacy remains limited. Our study introduces an injectable, temperature-controlled decellularized adipose tissue-alginate hydrogel loaded with dental pulp mesenchymal stem cells (DPMSCs) for in vivo fistula treatment.

View Article and Find Full Text PDF

Mitochondrial Electron Flow Dynamics Imaging for Assessing Mitochondrial Quality and Drug Screening.

Adv Sci (Weinh)

January 2025

State Key Laboratory of Advanced Drug Delivery and Release Systems, School of Pharmaceutical Sciences, Medical Science and Technology Innovation Center, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan, Shandong, 250117, P. R. China.

Mitochondrial quality control is paramount for cellular development, with mitochondrial electron flow (Mito-EF) playing a central role in maintaining mitochondrial homeostasis. However, unlike visible protein entities, which can be monitored through chemical biotechnology, regulating mitochondrial quality control by invisible entities such as Mito-EF has remained elusive. Here, a Mito-EF tracker (Mito-EFT) with a four-pronged probe design is presented to elucidate the dynamic mechanisms of Mito-EF's involvement in mitochondrial quality control.

View Article and Find Full Text PDF

Spondylolysis is defined as a defect or elongation in the pars interarticularis of the lumbar spine, either unilateral or bilateral. Growing children with bilateral spondylolysis may develop spondylolisthesis, i.e.

View Article and Find Full Text PDF

Audiovisual Breathing Guidance for Improved Image Quality and Scan Efficiency of T2- and Diffusion-Weighted Liver MRI.

Invest Radiol

January 2025

From the Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany (N.M., A.I., A.L., L.B., T.D., D. Kravchenko, D. Kuetting, C.C.P., J.A.L.); Quantitative Imaging Lab Bonn (QILaB), Bonn, Germany (N.M., A.I., L.B., D. Kravchenko, D. Kuetting, J.A.L.); Philips Healthcare, Hamburg, Germany (C.K.); Philips Medical Systems, Eindhoven, the Netherlands (A.H.-M.); and Department of Diagnostic and Interventional Radiology, University Hospital Aachen, Aachen, Germany (C.Y.).

Objectives: Impaired image quality and long scan times frequently occur in respiratory-triggered sequences in liver magnetic resonance imaging (MRI). We evaluated the impact of an in-bore active breathing guidance (BG) application on image quality and scan time of respiratory-triggered T2-weighted (T2) and diffusion-weighted imaging (DWI) by comparing sequences with standard triggering (T2S and DWIS) and with BG (T2BG and DWIBG).

Materials And Methods: In this prospective study, random patients with clinical indications for liver MRI underwent 3 T MRI with standard and BG acquisitions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!