Background: Open reduction and internal fixation of proximal humerus fractures can be difficult to achieve adequate, complication free results due to osteopenia of the proximal humerus and unstable fracture patterns. This study aimed to compare the biomechanical properties of a novel hybrid fixed angle blade plate (Fx plate) with an established fixed angle locking plate (PHILOS plate).

Methods: A two-part fracture was simulated in synthetic composite humeri by creating a transverse osteotomy and 10 mm fracture gap at the surgical neck. After treating the fractures with either an Fx plate or a PHILOS plate, humeral head was fixed and the shaft was displaced in a cantilever fashion. For elastic tests, loading was along the frontal and sagittal plane to achieve varus/valgus and extension/flexion, respectively. In plastic tests, loading was in a varus direction to determine the constructs' resistance to varus collapse.

Results: In elastic tests, both construct types had higher peak load and stiffness in extension/flexion than varus/valgus. Fx plate constructs were significantly stiffer than PHILOS constructs in varus/valgus (mean: 7.590/6.900 vs. 6.609/6.091 N/mm; p < 0.001 for both) but significantly less stiff in extension/flexion (8.770/9.541 vs. 9.533/9.997 N/mm; p < 0.001 for extension, p < 0.05 for flexion). In varus plastic tests, significantly higher peak loads were reported for Fx plate than PHILOS (134.391 vs. 115.531 N; p < 0.001).

Conclusions: In this fracture gap model, humeri implanted with a novel Fx plate provided higher varus/valgus stiffness but lower extension/flexion stiffness than a more traditional proximal humeral locking plate design (PHILOS).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5785900PMC
http://dx.doi.org/10.1186/s12938-018-0447-yDOI Listing

Publication Analysis

Top Keywords

proximal humerus
12
locking plate
8
fixation proximal
8
humerus fractures
8
fixed angle
8
plate philos
8
elastic tests
8
tests loading
8
plate
7
hybrid blade
4

Similar Publications

Background: Chondroblastoma is classified as a benign bone tumor. However, postoperative local recurrence remains a concern. We analyzed the factors contributing to chondroblastoma local recurrence and the clinical challenges associated with treating these patients.

View Article and Find Full Text PDF

Sexual dimorphism of the humerus bones in a French sample: comparison of several statistical models including machine learning models.

Int J Legal Med

January 2025

Faculté de Médecine, Institut Universitaire d'Anthropologie Médico-Légale, Université Côte d'Azur, 28 Avenue de Valombrose, Nice Cedex 2, 06107, France.

Sex estimation is an important part of skeletal analysis and forensic identification. Traditionally pelvic traits are utilized for accurate sex estimation. However, the long bones, especially humerus, have been proved to be as effective for determine the sex of the individual.

View Article and Find Full Text PDF

Background: The treatment of patients who suffer a proximal humeral fracture (PHF) remains controversial. The purpose of this study was to find consensus among experts using a validated iterative process in the treatment of patients after a PHF.

Methods: The Neer Circle is an organization of shoulder experts recognized for their service to the American Shoulder and Elbow Surgeons.

View Article and Find Full Text PDF

The aim of this study is to investigate whether not using the calcar screw in proximal humerus fractures affects functional and radiological outcomes. Thirty patients (21 females and 9 males) who presented with proximal humerus fractures and were treated with plate- screw fixation were evaluated. The patients were divided into two groups: group 1 included patients with the use of the calcar screw, and group 2 included patients without the calcar screw.

View Article and Find Full Text PDF

Fractures of the humerus are common on the midshaft of the bone, often causing injury to the nutrient artery. Successful fracture repair and healing requires preservation of the blood supply to the long bones which is conveyed through the nutrient foramina (NF). The topography of long bone NF varies in different populations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!