In this study, we retrospectively reviewed the experiences at our single institute in the treatment of malignant extrinsic ureteral obstruction (MUO) using ureteral stents to investigate the clinical outcomes and the predictive factors of stent failure. In 52 ureters of 38 patients who had radiologically significant hydronephrosis due to MUO, internal ureteral stents (The BARD(R) INLAY(TM) ureteral stent set) were inserted. The median follow-up interval after the initial stent insertion was 124.5 days (4-1,120). Stent failure occurred in 8 ureters (15.4%) of the 7 patients. The median interval from the first stent insertion to stent failure was 88 days (1-468). A Cox regression multivariate analysis showed that the significant predictors of stent failure were bladder invasion. Based on the possibility of stent failure, the adaptation of the internal ureteral stent placement should be considered especially in a patient with MUO combined with bladder invasion.

Download full-text PDF

Source
http://dx.doi.org/10.14989/ActaUrolJap_63_12_503DOI Listing

Publication Analysis

Top Keywords

stent failure
24
internal ureteral
12
stent
10
predictive factors
8
factors stent
8
treatment malignant
8
ureteral obstruction
8
ureteral stents
8
ureteral stent
8
stent insertion
8