Exploring kinetic energy as a new marker of cardiac function in the single ventricle circulation.

J Appl Physiol (1985)

Division of Imaging Sciences and Biomedical Engineering, King's College London, The Rayne Institute, St. Thomas' Hospital, London , United Kingdom.

Published: September 2018

Ventricular volumetric ejection fraction (VV EF) is often normal in patients with single ventricle circulations despite them experiencing symptoms related to circulatory failure. We sought to determine if kinetic energy (KE) could be a better marker of ventricular performance. KE was prospectively quantified using four-dimensional flow MRI in 41 patients with a single ventricle circulation (aged 0.5-28 yr) and compared with 43 healthy volunteers (aged 1.5-62 yr) and 14 patients with left ventricular (LV) dysfunction (aged 28-79 yr). Intraventricular end-diastolic blood was tracked through systole and divided into ejected and residual blood components. Two ejection fraction (EF) metrics were devised based on the KE of the ejected component over the total of both the ejected and residual components using 1) instantaneous peak KE to assess KE EF or 2) summating individual peak particle energy (PE) to assess PE EF. KE EF and PE EF had a smaller range than VV EF in healthy subjects (97.9 ± 0.8 vs. 97.3 ± 0.8 vs. 60.1 ± 5.2%). LV dysfunction caused a fall in KE EF ( P = 0.01) and PE EF ( P = 0.0001). VV EF in healthy LVs and single ventricle hearts was equivalent; however, KE EF and PE EF were lower ( P < 0.001) with a wider range indicating a spectrum of severity. Those reporting the greatest symptomatic impairment (New York Heart Association II) had lower PE EF than asymptomatic subjects ( P = 0.0067). KE metrics are markers of healthy cardiac function. PE EF may be useful in grading dysfunction. NEW & NOTEWORTHY Kinetic energy (KE) represents the useful work of the heart in ejecting blood. This article details the utilization of KE indexes to assess cardiac function in health and a variety of pathophysiological conditions. KE ejection fraction and particle energy ejection fraction (PE EF) showed a narrow range in health and a lower wider range in disease representing a spectrum of severity. PE EF was altered by functional status potentially offering the opportunity to grade dysfunction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7054048PMC
http://dx.doi.org/10.1152/japplphysiol.00580.2017DOI Listing

Publication Analysis

Top Keywords

single ventricle
16
ejection fraction
16
kinetic energy
12
cardiac function
12
ventricle circulation
8
patients single
8
ejected residual
8
particle energy
8
wider range
8
spectrum severity
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!