A study was undertaken to explore the use of volumetric modulated arc therapy (VMAT) for total body irradiation (TBI). Five patient plans were created in Pinnacle using nine 6 MV photon dynamic arcs. A dose of 12 Gy in six fractions was prescribed. The planning target volume (PTV) was split into four subsections for the head, chest, abdomen, and pelvis. The head and chest beams were optimized together, followed by the abdomen and pelvis beams. The last stage of the planning process involved turning all beams on and performing a final optimization to achieve a clinically acceptable plan. Beam isocenters were shifted by 3 or 5 mm in the left-right, anterior-posterior, and superior-inferior directions to simulate the effect of setup errors on the dose distribution. Treatment plan verification consisted of ArcCheck measurements compared to calculated doses using a global 3%/3 mm gamma analysis. All five patient plans achieved the planning aim of delivering 12 Gy to at least 90% of the target. The mean dose in the PTV was 12.7 Gy. Mean lung dose was restricted to 8 Gy, and a dose reduction of up to 40% for organs such as the liver and kidneys proved feasible. The VMAT technique was found to be sensitive to patient setup errors particularly in the superior-inferior direction. The dose predicted by the planning system agreed with measured doses and had an average pass rate of 99.2% for all arcs. VMAT was found to be a viable treatment technique for total body irradiation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5849856 | PMC |
http://dx.doi.org/10.1002/acm2.12257 | DOI Listing |
Psychiatry Clin Psychopharmacol
December 2024
Sleep and Disorders Unit, Division of Clinical Neurophysiology, Department of Neurology, Cerrahpasa Faculty of Medicine, Istanbul University-Cerrahpasa, İstanbul, Türkiye.
Background: Weighted blankets have recently introduced in the treatment on insomnia as a nonpharmacological integrative therapy. Here we prospectively evaluated the effects of weighted blankets on the sleep structure and heart rate variability (HRV) in patients with primary psychophysiological insomnia.
Methods: In this prospective polysomnographic (PSG) study between August 2021 and August 2022, patients were given weighted blankets (~10% of body weight) to use at home for 10 nights consecutively.
Viruses
December 2024
1st Internal Medicine Department, AHEPA University Hospital, School of Medicine, Aristotle University of Thessaloniki, 55436 Thessaloniki, Greece.
People with HIV (PWH) have an elevated risk of cardiovascular disease compared to those without HIV. This study aimed to investigate the relative serum expression of microRNAs (miRNAs) associated with arterial stiffness, a significant marker of cardiovascular disease. A total of 36 male PWH and 36 people without HIV, matched for age, body mass index, pack years, and dyslipidemia, were included in the study.
View Article and Find Full Text PDFViruses
December 2024
Gilead Sciences, Inc., Foster City, CA 94404, USA.
Ebola virus (EBOV) causes severe disease in humans, with mortality as high as 90%. The small-molecule antiviral drug remdesivir (RDV) has demonstrated a survival benefit in EBOV-exposed rhesus macaques. Here, we characterize the efficacy of multiple intravenous RDV dosing regimens on survival of rhesus macaques 42 days after intramuscular EBOV exposure.
View Article and Find Full Text PDFVaccines (Basel)
November 2024
Women's and Children's Health Network, North Adelaide, SA 5006, Australia.
Background/objectives: Influenza vaccination is recommended for pregnant women, offering the dual benefit of protecting pregnant women and their newborn infants against influenza. This study aimed to investigate the impact of body mass index (BMI) on influenza vaccine responses in pregnant women and their newborns.
Methods: Participants included pregnant women attending the Women's and Children's Hospital in South Australia between 2018 and 2021.
Sensors (Basel)
December 2024
National Institute of Physical Education of Catalonia (INEFC), 08038 Barcelona, Spain.
Several microtechnology devices quantify the external load of team sports using Global Positioning Systems sampling at 5, 10, or 15 Hz. However, for short, explosive actions, such as collisions, these sample rates may be limiting. It is known that very high-frequency sampling is capable of capturing changes in actions over a short period of time.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!