Functional characterization of cell-free expressed K1.3 channel using a voltage-sensitive fluorescent dye.

Protein Expr Purif

Univ. Grenoble Alpes, CEA, CNRS, IBS, F-38044, Grenoble, France; Univ. Grenoble Alpes, CNRS, INP, TheREx Team, TIMC-IMAG, F-38700, La Tronche, France. Electronic address:

Published: May 2018

Using a cell-free expression system, we produced the K1.3 protein embedded in one step within detergent micelles. The protein was then purified and relipidated into mixed lipid bilayers. These proteoliposomes held an average of 0.8 protein per liposome. We examined channel forming activity using an oxonol VI fluorescent probe and verified its inhibition using margatoxin and ShK toxins. This assay was automatized and optimized so as to get a Z' statistical factor acceptable for venom fraction screening. We obtained a sensible amount of membrane protein using the cell-free assay, that proved to be active when embedded in liposomes. These findings emphasize the quality of the cell-free produced K1.3 proteoliposomes and the usefulness of a fluorescent probe. This method can benefit the field of channel characterization, as well as provide tools for the development of new inhibitors, so as to reinforce our therapeutic arsenal against autoimmune diseases.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.pep.2018.01.006DOI Listing

Publication Analysis

Top Keywords

produced k13
8
fluorescent probe
8
functional characterization
4
cell-free
4
characterization cell-free
4
cell-free expressed
4
expressed k13
4
k13 channel
4
channel voltage-sensitive
4
voltage-sensitive fluorescent
4

Similar Publications

The emergence of parasites partially resistant to artemisinins (ART-R) poses a significant threat to recent gains in malaria control. ART-R has been associated with PfKelch13 (K13) mutations, which differ in fitness costs. This study investigates the gametocyte production and transmission fitness of African and Asian isolates with different K13 genotypes across multiple mosquito species.

View Article and Find Full Text PDF

Histatin 5 (Hst5) is a 24-amino-acid peptide naturally present in human saliva that has been proposed as a potential antifungal therapeutic. However, Hst5 is susceptible to degradation by secreted aspartyl proteases (Saps) produced by Candida albicans, which could limit its efficacy as a therapeutic. To better understand the role of the lysine residues of Hst5 in proteolysis by C.

View Article and Find Full Text PDF

Current malaria elimination targets must withstand a colossal challenge-resistance to the current gold standard antimalarial drug, namely artemisinin derivatives. If artemisinin resistance significantly expands to Africa or India, cases and malaria-related deaths are set to increase substantially. Spatial information on the changing levels of artemisinin resistance in Southeast Asia is therefore critical for health organisations to prioritise malaria control measures, but available data on artemisinin resistance are sparse.

View Article and Find Full Text PDF

Three dimensional (3D) gingival models in periodontal research: a systematic review.

J Mater Sci Mater Med

November 2023

Periodontology Unit, UCL Eastman Dental Institute, 21 University Street, London, WC1E 6DE, UK.

The aim of this study is to systematically appraise the evidence on available full thickness 3D gingival and mucosal models (3D culture in scaffold base system) and their application in periodontal and peri-implant research. This study involved a systematic review of twenty-two studies obtained from searching from five electronic databases: MEDLINE-OVID, EMBASE, EBSCOhost, Web of Science Core Collection and LILACS, as well as a hand search of eligible articles up to September 2022. A total of 2338 studies were initially identified, after removal of duplicates (573), abstracts/title selection (1765), and full text screening (95), twenty-two studies were included, thirty-seven models were identified.

View Article and Find Full Text PDF

A laser absorption spectroscopy diagnostic integrated within a hardened optical probe was used to measure temperature and water mole fraction at 500 kHz in post-detonation fireballs of explosives. In the experiments, an exploding-bridgewire detonator initiated a 25 g hemisphere of explosive (N5 or PETN). This produced a hemispherical fireball that traveled radially towards a hardened measurement probe.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!