The rapid and accurate detection of Cryptosporidium spp. is critically important for the prevention and timely treatment of cryptosporidiosis in AIDS patients (APs). This study was conducted to examine a UDG-LAMP technique for the first time to diagnose cryptosporidiosis in APs. After collecting demographic and clinical data, three stool samples were collected from the participants (120 volunteering APs). The microscopic examination of stained smears using the acid-fast method and the UDG-LAMP assay were performed for each sample. 10% of APs were infected with Cryptosporidium spp. The number of detected cryptosporidiosis cases using the acid-fast staining and UDG-LAMP methods were significantly different (P < 0.001). Diarrhea and weight loss were found to be significantly associated with cryptosporidiosis in patients (P < 0.05). The pretreatment of LAMP reagents with UDG successfully eliminated the likelihood of product re-amplification remaining from previous reactions. The UDG-LAMP technique could detect cryptosporidiosis in APs with high sensitivity and rapidity without carryover contamination.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.diagmicrobio.2017.12.017DOI Listing

Publication Analysis

Top Keywords

udg-lamp technique
12
detection cryptosporidium
8
aids patients
8
cryptosporidium spp
8
cryptosporidiosis aps
8
udg-lamp
5
cryptosporidium
5
cryptosporidiosis
5
aps
5
advanced uracil
4

Similar Publications

Background: Ocular infection with Toxoplasma gondii is a major preventable cause of blindness, especially in young people. The aim of the present study was to assess detection rate of T. gondii DNA in blood samples of clinically diagnosed of ocular toxoplasmosis using uracil DNA glycosylase-supplemented loop-mediated isothermal amplification (UDG-LAMP) and real-time quantitative PCR (qPCR) based on REP-529 and B1.

View Article and Find Full Text PDF

Diagnosis of toxoplasmosis is an important issue, especially in at-risk patients. The molecular methods showed a promising future for such diagnosis; however, the method itself and the target sequence to be detected is an important part of accurate detection of the infection. The aim of the present study was to evaluate the RE-529 sequence and B1 gene for Toxoplasma gondii detection in blood samples of the at-risk seropositive cases using uracil DNA glycosylase supplemented loop-mediated isothermal amplification (UDG-LAMP) assay.

View Article and Find Full Text PDF

Pseudomonas aeruginosa (P. aeruginosa) is an important opportunistic pathogen that causes serious infections in humans, including keratitis in contact lens wearers. Therefore, establishing a rapid, specific and sensitive method for the identification of P.

View Article and Find Full Text PDF

The rapid and accurate detection of Cryptosporidium spp. is critically important for the prevention and timely treatment of cryptosporidiosis in AIDS patients (APs). This study was conducted to examine a UDG-LAMP technique for the first time to diagnose cryptosporidiosis in APs.

View Article and Find Full Text PDF

We report a one-pot, closed-vessel enzymatic assay that eliminates carryover contamination while preserving robust DNA amplification in loop-mediated isothermal amplification (LAMP), providing reliable and rapid detection of target DNA in contaminated samples.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!