Objective: The present article reports how a dental implant with an internal port dental implant valve approach (DIVA) can be utilized as oroantral port to treat chronic rhinosinusitis (CRS) in a minimally invasive manner.
Method And Materials: Eleven patients (age mean 68.1 years) with CRS were subjected to the transimplant lavage technique. For three patients the CRS treatment was performed via previously installed dental implants, and for another eight patients the implantation procedure was combined with the CRS treatment. The moment the implant was fully installed, the sinus membrane was punctured via the implant channel. Upon completion of the pus drainage the sinus was irrigated with normal saline, followed by the injection of a steroid solution (100 mg hydrocortisone).
Results: Patients began to report symptomatic improvement from the first day after the first-session procedure. Nine patients had complete relief of most of their symptoms (nasal obstruction/discharge, anosmia/hyposmia) at day 30. The follow- up nasal endoscopy demonstrated no evidence of active sinus disease. All the implants used were found to be well-osseointegrated and still in use for prosthetic purposes. Clinical and radiologic results showed stability and no recurrence in the follow-up period.
Conclusion: The dental implant with an internal central port and integral dedicated sealing screw may be used for irrigation, observation, and further treatment of the maxillary sinus in cases of CRS.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3290/j.qi.a39742 | DOI Listing |
Imaging Sci Dent
December 2024
Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Assiut University, Assiut, Egypt.
Purpose: This study was performed to introduce, evaluate, and compare various novel assessment protocols designed for straightforward, reliable, and reproducible measurement of alveolar bone levels. These protocols are intended for standardized periodontal assessment and follow-up, utilizing cone-beam computed tomography (CBCT) images and manipulation of Digital Imaging and Communications in Medicine (DICOM) viewer software.
Materials And Methods: Two experienced oral and maxillofacial radiologists developed 5 distinct radiographic measurement protocols.
Imaging Sci Dent
December 2024
Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples Federico II, Naples, Italy.
Purpose: This study aimed to evaluate the impact of a metal artifact reduction (MAR) algorithm on cone-beam computed tomography (CBCT) scans of titanium and zirconia implants, both within and outside the field of view (FOV).
Materials And Methods: In this study, a dry human mandible was positioned in a CBCT scanner with only its left quadrant included in the FOV. Each type of implant (titanium and zirconia) was placed once in the right second premolar extraction socket and once in the left second premolar extraction socket of the mandible.
J Korean Assoc Oral Maxillofac Surg
December 2024
Department of Oral and Maxillofacial Surgery, Hallym University Sacred Heart Hospital, Anyang, Korea.
The submandibular displacement of a mandibular third molar residual root presents major challenges to oral and maxillofacial surgeons due to the proximity to critical anatomical structures such as the lingual nerve and sublingual artery. Preoperative imaging can approximate the location of the residual tooth root; however, accurately determining its exact position is difficult because of the dynamic nature of the mandible and the difficulty of real-time synchronization of imaging. This study presents the successful extraction of a residual mandibular third molar root in a 67-year-old female patient achieved using a magnetic field-based navigation system.
View Article and Find Full Text PDFJ Korean Assoc Oral Maxillofac Surg
December 2024
Department of Prosthodontics, Section of Dentistry, Seoul National University Bundang Hospital, Seongnam, Korea.
Objectives: The objective of this study was to evaluate the long-term clinical outcomes of one-piece narrow-diameter implants (NDIs), with diameters of 2.5 mm and 3.0 mm, and to investigate the factors that affect marginal bone loss (MBL) around these implants.
View Article and Find Full Text PDFJ Indian Soc Periodontol
December 2024
Department of Periodontology and Implantology, G. Pulla Reddy Dental College and Hospital, Kurnool, Andhra Pradesh, India.
Background: The present study aims to evaluate a three-dimensional (3D) changes in the crestal bone levels (buccally, lingually/palatally, mesially, and distally) and in the thickness of keratinized tissue around single or multiple implants using cone-beam computed tomography (CBCT) after 1 year.
Materials And Methods: Twenty-eight implants were placed in the posterior load-bearing areas in 10 patients. The crestal bone levels and the thickness of keratinized tissue surrounding the edentulous area were assessed preoperatively, immediately after implant placement, and 1 year after implant placement using CBCT (3D imaging technique with DICOM software (Carestream Health, Rochester, NY)).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!