A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Twenty years of FISH-based translocation analysis for retrospective ionizing radiation biodosimetry. | LitMetric

Purpose: The fluorescent in situ hybridization (FISH) technique, which easily detects reciprocal translocations, is currently used to estimate doses in retrospective biological dosimetry, after suspected accidental overexposure to ionizing radiation (IR). This study of 42 cases aimed to verify the appropriateness of this assay for radiation dose reconstruction, compared to the dicentric assay, and to evaluate other limitations.

Material And Methods: We labeled chromosomes 2, 4, and 12 by 3-color FISH painting to detect translocations on lymphocytes of patients with suspected past IR overexposure.

Result: Translocation dose estimation showed doses significantly different from 0 Gy in 25 of the 42 cases. The lowest positive dose measured was 0.3 Gy. Several months after IR exposure, the doses measured by translocation and dicentric assays are quite similar. For a year, dose estimation by translocation assay becomes more relevant as dicentric frequency starts to decrease, coming close to 0 for more than a year after the exposure. The persistence of translocations enabled us to corroborate an overexposure 44 years earlier. Interpretation of the observed translocation yield requires the knowledge of the patient's other radiation exposures. A dose assessment by this biomarker is relevant only if the radiation exposure is confirmed.

Conclusions: This technique is appropriate for corroborating a former IR exposure of individuals. When the radiation dose is greater than 1 Gy, the translocations in complex exchanges must be considered. Another relevant point is the use of an appropriate background yield of translocations. The dose assessment, however, also depends on exposure to various genotoxic agents besides IR. If no evidence about the existence of radiation exposure is available, dose assessment is not useful. For this reason, report only the translocation frequency and its comparison with the background yield by age class is preferable.

Download full-text PDF

Source
http://dx.doi.org/10.1080/09553002.2018.1427903DOI Listing

Publication Analysis

Top Keywords

dose assessment
12
ionizing radiation
8
dose
8
radiation dose
8
dose estimation
8
radiation exposure
8
background yield
8
radiation
7
translocation
6
exposure
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!