Errors in the Use of Inhalers by Health Care Professionals: A Systematic Review.

J Allergy Clin Immunol Pract

Department of Respiratory Medicine, Hospital de la Santa Creu i Sant Pau, Institut d'Investigació Biomèdica Sant Pau (IIB Sant Pau), Universitat Autònoma de Barcelona, Barcelona, Spain.

Published: October 2019

Background: Inefficient inhaler technique (IT) compromises the optimal delivery of medication. However, the IT knowledge of health care professionals (HCPs) has received scant attention.

Objective: The objective of this study was to perform a systematic review of published reports assessing the IT proficiency of HCPs in using pressurized metered dose (pMDI) and dry powder (DPI) inhalers.

Methods: Studies published between 1975 and 2014 that directly assessed the IT skills of HCPs were selected according to predefined selection criteria.

Results: Data were extracted from 55 studies involving 6,304 HCPs who performed 9,996 tests to demonstrate their IT proficiency. Overall, the IT was considered correct in 15.5% of cases (95% confidence interval [CI], 12-19.3), decreasing over time from 20.5% (95% CI, 14.9-26.8) from the early period (defined as 1975-1995) to 10.8% (95% CI, 7.3-14.8) during the late period (1996-2014). The most common errors in the use of pMDIs were as follows: not breathing out completely before inhalation (75%; 95% CI, 56-90), lack of coordination (64%; 95% CI, 29-92), and postinhalation breath-hold (63%; 95% CI, 52-72). The most common errors using DPI were deficient preparation (89%; 95% CI, 82-95), not breathing out completely before inhalation (79%; 95% CI, 68-87), and no breath-hold (76%; 95% CI, 67-84).

Conclusions: HCPs demonstrated inadequate knowledge of the proper use of inhalers. The poor understanding of the correct use of these devices may prevent these professionals from being able to adequately assess and teach proper inhalation techniques to their patients.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jaip.2017.12.032DOI Listing

Publication Analysis

Top Keywords

95%
9
health care
8
care professionals
8
systematic review
8
common errors
8
breathing completely
8
completely inhalation
8
hcps
5
errors inhalers
4
inhalers health
4

Similar Publications

Article Synopsis
  • The study measured fibrinogen fluorescence at temperatures between 20 and 80 degrees Celsius across different pH levels.
  • It was found that raising the temperature from 20 to 40 degrees Celsius did not change the structure of fibrinogen in solutions with pH between 4.5 and 9.3.
  • However, temperatures between 40 to 50 degrees Celsius caused some structural changes in neutral solutions, and temperatures above 50-55 degrees Celsius led to significant denaturation of the fibrinogen molecule.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!