A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Measurements of Enthalpy of Sublimation of Ne, N, O, Ar, CO, Kr, Xe, and HO using a Double Paddle Oscillator. | LitMetric

We report precise experimental values of the enthalpy of sublimation (Δ ) of quenched condensed films of neon (Ne), nitrogen (N), oxygen (O), argon (Ar), carbon dioxide (CO), krypton (Kr), xenon (Xe), and water (HO) vapor using a single consistent measurement platform. The experiments are performed well below the triple point temperature of each gas and fall in the temperature range where existing experimental data is very limited. A 6 cm and 400 µm thick double paddle oscillator (DPO) with high quality factor (Q ≈ 4 × 10 at 298K) and high frequency stability (33 parts per billion) is utilized for the measurements. The enthalpies of sublimation are derived by measuring the rate of mass loss during temperature programmed desorption. The mass change is detected due to change in the resonance frequency of the self-tracking oscillator. Our measurements typically remain within 10% of the available literature, theory, and National Institute of Standards and Technology (NIST) () values, but are performed using an internally consistent method across different gases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5772914PMC
http://dx.doi.org/10.1016/j.jct.2017.11.004DOI Listing

Publication Analysis

Top Keywords

enthalpy sublimation
8
double paddle
8
paddle oscillator
8
measurements enthalpy
4
sublimation double
4
oscillator report
4
report precise
4
precise experimental
4
experimental values
4
values enthalpy
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!