A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Carotid Doppler sonography: additional tool to assess hemodynamic improvement after transcatheter aortic valve implantation. | LitMetric

Purpose: The aim of our study was to assess the arterial cerebral blood flow variations in patients with aortic valve stenosis, immediately after the transcatheter aortic valve implantation (TAVI).

Methods: The study population includes 62 consecutive patients who underwent TAVI for aortic valve stenosis (95%) and sugical bioprosthesis degeneration (5%). Carotid Doppler examination was performed recording blood flow, systolic peak velocity, time average mean velocity and mean acceleration time at baseline, after balloon aortic valvuloplasty, and within 10 min after the device release.

Results: A significant improvement of blood flow was recorded at the end of the procedure (from 315.05 ± 141.72 to 538.67 ± 277.46 ml/min; P < 0.00001). The systolic peak velocity and the time average mean velocity increased from 52.27 ± 14.29 to 78.89 ± 20.48 cm/s (P < 0.00001) and from 12.24 ± 4.74 to 21.21 ± 9 cm/s (P < 0.00001), respectively. Consensually, the mean acceleration time decreased from 0.22 ± 0.02 to 0.03 ± 0.02 s (P < 0.00001) after the procedure.

Conclusion: Monitoring of Doppler measurements may be a useful and noninvasive method to assess acutely the improvement of hemodynamic flow after TAVI, specifically for the cerebral district.

Download full-text PDF

Source
http://dx.doi.org/10.2459/JCM.0000000000000622DOI Listing

Publication Analysis

Top Keywords

aortic valve
16
blood flow
12
carotid doppler
8
transcatheter aortic
8
valve implantation
8
valve stenosis
8
aortic
5
doppler sonography
4
sonography additional
4
additional tool
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!