AI Article Synopsis

  • Non-invasive ischaemia tests and biomarkers are commonly used in emergency departments to rule out acute coronary syndrome, but their diagnostic accuracy is still not fully established.
  • A systematic review analyzed 77 studies with over 49,000 patients comparing various tests for diagnosing chest pain, revealing that fast and six-hour highly sensitive troponin T protocols have similar sensitivity and specificity.
  • Among non-invasive tests, coronary computed tomography and myocardial perfusion scintigraphy demonstrated the highest diagnostic accuracy for patients without elevated troponin levels, while stress echography was less effective and exercise testing performed the worst.

Article Abstract

Background: Non-invasive ischaemia tests and biomarkers are widely adopted to rule out acute coronary syndrome in the emergency department. Their diagnostic accuracy has yet to be precisely defined.

Methods: Medline, Cochrane Library CENTRAL, EMBASE and Biomed Central were systematically screened (start date 1 September 2016, end date 1 December 2016). Prospective studies (observational or randomised controlled trial) comparing functional/imaging or biochemical tests for patients presenting with chest pain to the emergency department were included.

Results: Overall, 77 studies were included, for a total of 49,541 patients (mean age 59.9 years). Fast and six-hour highly sensitive troponin T protocols did not show significant differences in their ability to detect acute coronary syndromes, as they reported a sensitivity and specificity of 0.89 (95% confidence interval 0.79-0.94) and 0.84 (0.74-0.9) vs 0.89 (0.78-0.94) and 0.83 (0.70-0.92), respectively. The addition of copeptin to troponin increased sensitivity and reduced specificity, without improving diagnostic accuracy. The diagnostic value of non-invasive tests for patients without troponin increase was tested. Coronary computed tomography showed the highest level of diagnostic accuracy (sensitivity 0.93 (0.81-0.98) and specificity 0.90 (0.93-0.94)), along with myocardial perfusion scintigraphy (sensitivity 0.85 (0.77-0.91) and specificity 0.92 (0.83-0.96)). Stress echography was inferior to coronary computed tomography but non-inferior to myocardial perfusion scintigraphy, while exercise testing showed the lower level of diagnostic accuracy.

Conclusions: Fast and six-hour highly sensitive troponin T protocols provide an overall similar level of diagnostic accuracy to detect acute coronary syndrome. Among the non-invasive ischaemia tests for patients without troponin increase, coronary computed tomography and myocardial perfusion scintigraphy showed the highest sensitivity and specificity.

Download full-text PDF

Source
http://dx.doi.org/10.1177/2048872617754275DOI Listing

Publication Analysis

Top Keywords

diagnostic accuracy
20
tests patients
16
emergency department
12
acute coronary
12
coronary computed
12
computed tomography
12
level diagnostic
12
myocardial perfusion
12
perfusion scintigraphy
12
biochemical tests
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!