Visible spectrum photodetector devices fabricated using molecular crystals of carbon C are reported. The devices operate efficiently, extending over and beyond the full visible light spectrum (300-710 nm) with a bias voltage tunable responsivity of 4 mA-0.5 mA W . Across this range of wavelengths, the noise equivalent power of these devices remains below 10 nW Hz , providing a detectivity of 10 Jones. The noise current in these devices is found to have a strong dependence on both bias voltage and frequency, varying by 4 orders of magnitude from 1 nA Hz to 0.1 pA Hz . The devices also display a near-linear dependence of photocurrent on light intensity over 4 orders of magnitude, providing a dynamic range approaching 80 dB. The 3 dB bandwidth of the devices is found to be above 10 Hz, while the 18 dB bandwidth exceeds 1 kHz. The transient photocurrents of the devices have a rise time of ≈50 µs and a long fall time of ≈4 ms. The spectral photocurrent of the devices is found to quench gradually with a reduction in temperature from ≈300 K and is fully quenched at temperatures below T ≈ 100 K. Upon reheating, the device performance is fully recovered.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/smll.201703624 | DOI Listing |
Int J Biol Macromol
January 2025
Centre of Advanced Study in Marine Biology, Annamalai University, Parangipettai 608 502, Tamil Nadu, India.
A bio-fabrication approach is a novel way to develop chitosan-stabilized magnesium oxide nanomaterials (cMgO-NMs). The process involves utilizing polymeric chitosan as the reducing and stabilizing agent. The characteristics of the developed cMgO-NMs were determined using various spectroscopical techniques.
View Article and Find Full Text PDFTalanta
January 2025
Institute of Chemistry of Renewable Resources, Department of Chemistry, BOKU University, Konrad-Lorenz-Straße 24, 3430, Tulln, Austria. Electronic address:
Chromatographic separations in combination with spectroscopic detectors are a main pillar of today's analytical chemistry. The recorded spectroscopic data is usually not shown in a typical chromatogram, therefore the contained additional information cannot be accessed readily by the analyst and is inspected in tedious additional routines, such as separate database searches. We developed a method to add colors to gas chromatograms with mass spectral detection.
View Article and Find Full Text PDFJ Fluoresc
January 2025
Department of Physics, Jnana Bharathi Campus, Bangalore University, Bengaluru, 560056, India.
This investigation delves into the extraction of polyphenols from the flowers of Tabebuia rosea using a basic maceration approach with acetone, ethanol, and methanol as solvents. The spectroscopic analysis of the dye obtained confirms the existence of functional groups in the polyphenol extract. The study also explores optoelectronic, fluorescence, and photometric characteristics associated with polyphenols.
View Article and Find Full Text PDFRetin Cases Brief Rep
January 2025
New England Eye Center, Tufts Medical Center, Boston, MA.
Purpose: To describe a case of stellate multiform amelanotic choroidopathy (SMACH) with focal hyperfluorescence on indocyanine green angiography (ICGA).
Methods: Case report.
Results: A 19-year-old Caucasian woman was seen for an asymptomatic choroidal lesion.
J Phys Chem A
January 2025
Department of Chemistry and Dodd Walls Centre, University of Otago, Dunedin 9016, New Zealand.
Three triphenylamine-Indane donor-acceptor dyes with different functional groups on the acceptor were studied to investigate how substitution would affect the optical properties. The dyes studied were IndCN, containing two malononitrile groups; InO, with two ketone groups; and InOCN, which features mixed functional groups. A combination of Raman spectroscopy, UV-vis absorption and emission spectroscopy, and density functional theory (DFT) calculations were employed for characterization.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!