Asthma and chronic obstructive pulmonary disease (COPD) patients are required to inhale forcefully and deeply to receive medication when using a dry powder inhaler (DPI). There is a clinical need to objectively monitor the inhalation flow profile of DPIs in order to remotely monitor patient inhalation technique. Audio-based methods have been previously employed to accurately estimate flow parameters such as the peak inspiratory flow rate of inhalations, however, these methods required multiple calibration inhalation audio recordings. In this study, an audio-based method is presented that accurately estimates inhalation flow profile using only one calibration inhalation audio recording. Twenty healthy participants were asked to perform 15 inhalations through a placebo Ellipta™ DPI at a range of inspiratory flow rates. Inhalation flow signals were recorded using a pneumotachograph spirometer while inhalation audio signals were recorded simultaneously using the Inhaler Compliance Assessment device attached to the inhaler. The acoustic (amplitude) envelope was estimated from each inhalation audio signal. Using only one recording, linear and power law regression models were employed to determine which model best described the relationship between the inhalation acoustic envelope and flow signal. Each model was then employed to estimate the flow signals of the remaining 14 inhalation audio recordings. This process repeated until each of the 15 recordings were employed to calibrate single models while testing on the remaining 14 recordings. It was observed that power law models generated the highest average flow estimation accuracy across all participants (90.89±0.9% for power law models and 76.63±2.38% for linear models). The method also generated sufficient accuracy in estimating inhalation parameters such as peak inspiratory flow rate and inspiratory capacity within the presence of noise. Estimating inhaler inhalation flow profiles using audio based methods may be clinically beneficial for inhaler technique training and the remote monitoring of patient adherence.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5773205PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0191330PLOS

Publication Analysis

Top Keywords

inhalation flow
20
inhalation audio
20
flow
12
flow profile
12
inhalation
12
inspiratory flow
12
power law
12
audio-based methods
8
estimate flow
8
parameters peak
8

Similar Publications

Modeling aerosol dynamics in the airways is challenging, and most modern personalized tools consider only a single inhalation maneuver through less than 10% of the total lung volume. Here, we present an modeling pipeline to produce a device that preserves patient-specific upper airways while approximating deeper airways, capable of achieving total lung volumes over 7 liters. The modular system, called TIDAL, includes tunable inhalation and exhalation breathing capabilities with resting flow rates up to 30 liters per minute.

View Article and Find Full Text PDF

Sevoflurane is an inhalation anesthetic widely used for general anesthesia, but its genotoxic potential is controversial in clinical studies. It is unknown whether the effects are due to surgery or the anesthetic. Thus, for the first time, the present study investigated genotoxicity in peripheral blood cells and in target organs (liver, lung, and kidney) and micronucleus (MN) in the bone marrow of a single exposure to sevoflurane at three different concentrations in monitored mice.

View Article and Find Full Text PDF

Hydrogen inhalation exerts anti-seizure effects by preventing oxidative stress and inflammation in the hippocampus in a rat model of kainic acid-induced seizures.

Neurochem Int

December 2024

School of Medicine, Fu Jen Catholic University, New Taipei City, 24205, Taiwan; Research Center for Chinese Herbal Medicine, College of Human Ecology, Chang Gung University of Science and Technology, Taoyuan City, 33303, Taiwan. Electronic address:

Hydrogen gas (H) is an antioxidant with demonstrated neuroprotective efficacy. In this study, we administered H via inhalation to rats to evaluate its effects on seizures induced by kainic acid (KA) injection and the underlying mechanism. The animals were intraperitoneally injected with KA (15 mg/kg) to induce seizures.

View Article and Find Full Text PDF

The role of home polygraphy sleep studies in the diagnosis of catathrenia.

J Sleep Res

December 2024

Department of Respiratory and Sleep Sciences, UHCW NHS Trust, Coventry, UK.

Catathrenia is an uncommon sleep disorder. Having been originally classified as a parasomnia it is now considered a sleep related breathing disorder. Polysomnography (PSG) is the gold standard for diagnosing catathrenia which demonstrates a classic pattern of a deep inhalation followed by a protracted exhalation, accompanied by groaning sounds.

View Article and Find Full Text PDF

Middle Eastern countries, such as the United Arab Emirates and Oman, are affected by frequent dust storms and extreme hot climatic conditions, which can exacerbate respiratory conditions. These environmental factors are particularly injurious to asthmatic patients, as they can aggravate small airway disease (SAD), leading to increased morbidity and healthcare challenges. The evaluation of maximal mid-expiratory flow (MEF-25) as a diagnostic and therapeutic tool for early-stage small airway dysfunction is of significant clinical importance, particularly in hot and arid metropolitan environments where dusty conditions exacerbate pulmonary issues.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!