A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of an external-to-internal convertible endoscopic biliary drainage device - a preliminary prospective feasibility study. | LitMetric

Background And Study Aims:  Endoscopic nasobiliary drainage (ENBD) for a malignant stricture in the bile duct has some advantages over endoscopic biliary stenting (EBS). However, ENBD may cause nasopharyngeal discomfort. We developed an external-to-internal convertible endoscopic biliary drainage (ETI-EBD) device that enables both internal and external drainage to occur during a single endoscopy.

Patients And Methods: This device consists of three parts, comprising a 5-Fr ENBD tube (250 cm) (ENBD-t), an 8.5-Fr EBS tube (7 cm) (EBS-t), and an 8-Fr pusher tube for EBS (230 cm) (P-t). The EBS-t is mounted over the ENBD-t at the distal end of the ENBD-t. The P-t is also placed over the ENBD-t. After an endoscopic sphincterotomy, the EBS-t of the device is inserted into the papilla, then the duodenal endoscope is withdrawn, leaving the device in place. After ENBD, only the ENBD-t was withdrawn from the P-t. At this point, the EBS-t was isolated and left without endoscopy or radiography.

Results: ETI-EBD was successfully placed in all consecutive 21 patients (100 %). The release of EBS-t from ENBD-t wit was successfully completed in 19 patients (90.5 %). There were 4 patients with kink of P-t when exchanging this device from the mouth to the nose. It was difficult for 2 patients to withdraw the ENBD-t because of poor lubrication performance. There were no significant complications associated with the use of the device.

Conclusion: This device allows for both external and internal biliary drainage with a single endoscopy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5770265PMC
http://dx.doi.org/10.1055/s-0043-123934DOI Listing

Publication Analysis

Top Keywords

endoscopic biliary
12
biliary drainage
12
external-to-internal convertible
8
convertible endoscopic
8
device
7
enbd-t
7
drainage
5
ebs-t
5
development external-to-internal
4
endoscopic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!