Objective: The aim of this study was to define the critical warning sign of real-time brainstem auditory evoked potential (BAEP) for predicting hearing loss (HL) after microvascular decompression (MVD) for hemifacial spasm (HFS).

Methods: Nine hundred and thirty-two patients with HFS who underwent MVD with intraoperative monitoring (IOM) of BAEP were analyzed. We used a 43.9 Hz/s stimulation rate and 400 averaging trials to obtain BAEP. To evaluate HL, pure-tone audiometry and speech discrimination scoring were performed before and one week after surgery. We analyzed the incidence for postoperative HL according to BAEP changes and calculated the diagnostic accuracy of significant warning criteria.

Results: Only 11 (1.2%) patients experienced postoperative HL. The group showing permanent loss of wave V showed the largest percentage of postoperative HL (p < 0.001). No patient who experienced only latency prolongation (≥1 ms) had postoperative HL. Loss of wave V and latency prolongation (≥1 ms) with amplitude decrement (≥50%) were highly associated with postoperative HL.

Conclusions: Loss of wave V and latency prolongation of 1 ms with amplitude decrement ≥50% were the critical warning signs of BAEP for predicting postoperative HL.

Significance: These findings elucidate the critical warning sign of real-time BAEP.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinph.2017.12.032DOI Listing

Publication Analysis

Top Keywords

critical warning
8
warning sign
8
sign real-time
8
real-time brainstem
8
brainstem auditory
8
auditory evoked
8
microvascular decompression
8
hemifacial spasm
8
evoked potentials
4
potentials microvascular
4

Similar Publications

What Is Already Known About This Topic?: Public health laboratories (PHLs) are critical for effectively identifying, detecting, preventing, and responding to emerging and reemerging infectious diseases. Following the 2014 Ebola outbreak, Sierra Leone implemented a national laboratory strategic plan (2015-2020) aimed at creating, strengthening, and maintaining laboratory capacities for detecting, assessing, notifying, and reporting incidents, with a requirement to review PHL capabilities every five years.

What Is Added By This Report?: This study assessed the comprehensive capacity and personnel status of PHLs in Sierra Leone using a standardized assessment tool following the implementation of the 2015 National Laboratory Strategic Plan.

View Article and Find Full Text PDF

Background: Hookah tobacco smoking is prevalent among youth and young adults. While health warning labels play a critical role in communicating the health risks of tobacco product use to consumers, compliance with US Federal Regulation's nicotine warning requirements on hookah tobacco packaging is low. Some labelling suggests that consumers are exposed to 'only 0.

View Article and Find Full Text PDF

Background: Initial ED assessment can use early warning scores to identify and prioritise patients who need time-critical treatment. We aimed to determine the accuracy of the National Early Warning Score version 2 (NEWS2) for predicting the need for time-critical treatment.

Methods: We undertook a single-centre retrospective observational cohort study.

View Article and Find Full Text PDF

Artificial Intelligence in Sepsis Management: An Overview for Clinicians.

J Clin Med

January 2025

Anesthesiology, Critical Care and Pain Medicine Division, Department of Medicine and Surgery, University of Parma, Viale Gramsci 14, 43126 Parma, Italy.

Sepsis is one of the leading causes of mortality in hospital settings, and early diagnosis is a crucial challenge to improve clinical outcomes. Artificial intelligence (AI) is emerging as a valuable resource to address this challenge, with numerous investigations exploring its application to predict and diagnose sepsis early, as well as personalizing its treatment. Machine learning (ML) models are able to use clinical data collected from hospital Electronic Health Records or continuous monitoring to predict patients at risk of sepsis hours before the onset of symptoms.

View Article and Find Full Text PDF

Implantable Passive Sensors for Biomedical Applications.

Sensors (Basel)

December 2024

School of Electrical and Computer Engineering, National Technical University of Athens, 15772 Athens, Greece.

Article Synopsis
  • Implantable sensors are becoming popular for localized and continuous monitoring in medical settings, allowing for early detection and timely interventions.
  • There are two main types of implantable sensors: active, which have more advanced functionalities but require a power source, and passive, which don't need power and offer simpler, smaller designs.
  • This review focuses on passive sensor technologies, discussing their materials, detection methods, clinical applications, advantages over active sensors, and important considerations for their packaging and compatibility with the human body.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!