Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Some patients undergoing breast reconstruction require post-mastectomy radiation therapy, but the metallic ports used in temporary tissue expanders attenuate the X-rays. In this study, we evaluated by the film method, the attenuation of 4 MV and 6 MV X-rays after passing through a metallic port, with the aim of identifying a useful method for determining the appropriate density to use in the radiation treatment planning system (RTPS), taking into account the distance between the metallic port and the targets. Radiochromic film was used to measure depth doses after the X-rays passed through the metallic port. The physical density allotted to the metal port portion was varied on the RTPS within the range 1-16 g/cm3, and the physical density values were calculated that best reproduced the depth-dose distribution extrapolated from the film method. When the metallic port was orientated perpendicularly, the attenuation of the X-rays peaked at ~7% at both 4 MV and 6 MV. In the parallel orientation, the X-rays were attenuated by up to ~40% at 4 MV and by up to ~30% at 6 MV. We estimated the optimum physical density to be 9.8 g/cm3, which yielded the best fit with the actual measurements. We demonstrated the most likely range for the target depth from the CT images of actual patients and, within this range, we identified the optimum physical density at which the measured and calculated values were most consistent with each other.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5951076 | PMC |
http://dx.doi.org/10.1093/jrr/rrx085 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!