Background: The rate of cardiovascular implantable electronic device infection (CIEDI) has increased, despite the use of perioperative antibiotics at the time of device placement or revision. This is due, in part, to the presence of multiple comorbid conditions in an elderly population, in general, who require CIED. Statins may have an antibacterial effect, although there is currently no evidence that the likelihood of CIEDI has been impacted by statin use.
Methods: A retrospective cohort study was performed to assess whether statins are associated with a reduced risk of CIEDI. The VA Informatics and Computing Infrastructure (VINCI) database, which includes all veterans who underwent CIED placement between 2008 and 2015, was used. A logistic regression model was constructed to estimate the adjusted risk of CIEDI among patients who were receiving statins after adjusting for confounding factors.
Results: Overall, 18,970 CIED procedures were included, and 98% of them were performed in men with a mean age of 71 ± 11 years. The rate of diabetes mellitus, heart failure, advanced chronic kidney diseases, CIEDI, positive methicillin-resistant Staphylococcus aureus nasal colonization, and statin use were 23%, 15.7%, 3.3%, 1.14%, 12.6%, and 56%, respectively. The logistic regression analysis showed that statins were significantly associated with a reduced risk of CIEDI; after controlling for other effects, the reduction was 66% (odds ratio 0.34 [0.2-0.59], P-value < 0.001). The effect of statins was confirmed by propensity score analysis.
Conclusions: Our study showed that among patients receiving statins who had undergone CIED placement, there was a 66% reduction in subsequent CIEDI.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/pace.13285 | DOI Listing |
Sci Rep
December 2024
Department of Medical and Surgical Sciences, Institute of Cardiology, University of Bologna, Policlinico S.Orsola-Malpighi, via Massarenti 9, Bologna, 40138, Italy.
Cardiac implantable electronic devices infections (CIEDI) are associated with poor survival despite the improvement in transvenous lead extraction (TLE). Aetiology and systemic involvement are driving factors of clinical outcomes. The aim of this study was to explore their contribute on overall mortality.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
March 2023
Department of Medicine, Clinical & Translational Research Center, Buffalo, New York, USA.
Introduction: Cardiac Implantable Electronic Devices (CIEDs) are widely used for the management of advanced heart failure and ventricular arrhythmias. CIED-Infection (CIED-I) has very high mortality, especially in the subsets of patients with limited health-care access and delayed presentation. The purpose of this study is to identify the risk-predictors mortality in subjects with CIED-I.
View Article and Find Full Text PDFBMC Med Inform Decis Mak
September 2019
Department of Cardiology, Xinhua Hospital, School of Medicine, Shanghai Jiao Tong University, 1665#, KongJiang Road, Shanghai, 200092, China.
Background: The incidence of cardiac implantable electronic device infection (CIEDI) is low and usually belongs to the typical imbalanced dataset. We sought to describe our experience on the management of the imbalanced CIEDI dataset.
Methods: Database from two centers of patients undergoing device implantation from 2001 to 2016 were reviewed retrospectively.
Pacing Clin Electrophysiol
November 2018
Medical Service, Washington DC VA Medical Center, Washington, DC, USA.
Background: Cefazolin is used as standard preoperative prophylaxis for a variety of surgical procedures that involve the skin. In contrast, vancomycin is recommended for a minority of patients, specifically those with an IgE-mediated allergy to beta-lactams and considered in patients with known colonization with methicillin-resistant Staphylococcus aureus or at high risk for such. Vancomycin, however, has been overprescribed, has nephrotoxicity risk, and may be less effective due to its inferior coverage of methicillin-susceptible S.
View Article and Find Full Text PDFEur J Nucl Med Mol Imaging
January 2019
Cardiology Division, Department of Diagnostics, Clinical and Public Health Medicine, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy.
Purpose: F-FDG PET/CT is an emerging technique for diagnosis of cardiac implantable electronic devices infection (CIEDI). Despite the improvements in transvenous lead extraction (TLE), long-term survival in patients with CIEDI is poor. The aim of the present study was to evaluate whether the extension of CIEDI at F-FDG PET/CT can improve prediction of survival after TLE.