Background: The rate of cardiovascular implantable electronic device infection (CIEDI) has increased, despite the use of perioperative antibiotics at the time of device placement or revision. This is due, in part, to the presence of multiple comorbid conditions in an elderly population, in general, who require CIED. Statins may have an antibacterial effect, although there is currently no evidence that the likelihood of CIEDI has been impacted by statin use.

Methods: A retrospective cohort study was performed to assess whether statins are associated with a reduced risk of CIEDI. The VA Informatics and Computing Infrastructure (VINCI) database, which includes all veterans who underwent CIED placement between 2008 and 2015, was used. A logistic regression model was constructed to estimate the adjusted risk of CIEDI among patients who were receiving statins after adjusting for confounding factors.

Results: Overall, 18,970 CIED procedures were included, and 98% of them were performed in men with a mean age of 71 ± 11 years. The rate of diabetes mellitus, heart failure, advanced chronic kidney diseases, CIEDI, positive methicillin-resistant Staphylococcus aureus nasal colonization, and statin use were 23%, 15.7%, 3.3%, 1.14%, 12.6%, and 56%, respectively. The logistic regression analysis showed that statins were significantly associated with a reduced risk of CIEDI; after controlling for other effects, the reduction was 66% (odds ratio 0.34 [0.2-0.59], P-value < 0.001). The effect of statins was confirmed by propensity score analysis.

Conclusions: Our study showed that among patients receiving statins who had undergone CIED placement, there was a 66% reduction in subsequent CIEDI.

Download full-text PDF

Source
http://dx.doi.org/10.1111/pace.13285DOI Listing

Publication Analysis

Top Keywords

risk ciedi
12
cardiovascular implantable
8
implantable electronic
8
electronic device
8
device infection
8
cohort study
8
statins associated
8
associated reduced
8
reduced risk
8
logistic regression
8

Similar Publications

Prognostic role of aetiological agent vs. clinical pattern in candidates to lead extraction for cardiac implantable electronic device infections.

Sci Rep

December 2024

Department of Medical and Surgical Sciences, Institute of Cardiology, University of Bologna, Policlinico S.Orsola-Malpighi, via Massarenti 9, Bologna, 40138, Italy.

Cardiac implantable electronic devices infections (CIEDI) are associated with poor survival despite the improvement in transvenous lead extraction (TLE). Aetiology and systemic involvement are driving factors of clinical outcomes. The aim of this study was to explore their contribute on overall mortality.

View Article and Find Full Text PDF

Introduction: Cardiac Implantable Electronic Devices (CIEDs) are widely used for the management of advanced heart failure and ventricular arrhythmias. CIED-Infection (CIED-I) has very high mortality, especially in the subsets of patients with limited health-care access and delayed presentation. The purpose of this study is to identify the risk-predictors mortality in subjects with CIED-I.

View Article and Find Full Text PDF

Risk factor analysis of device-related infections: value of re-sampling method on the real-world imbalanced dataset.

BMC Med Inform Decis Mak

September 2019

Department of Cardiology, Xinhua Hospital, School of Medicine, Shanghai Jiao Tong University, 1665#, KongJiang Road, Shanghai, 200092, China.

Background: The incidence of cardiac implantable electronic device infection (CIEDI) is low and usually belongs to the typical imbalanced dataset. We sought to describe our experience on the management of the imbalanced CIEDI dataset.

Methods: Database from two centers of patients undergoing device implantation from 2001 to 2016 were reviewed retrospectively.

View Article and Find Full Text PDF

Background: Cefazolin is used as standard preoperative prophylaxis for a variety of surgical procedures that involve the skin. In contrast, vancomycin is recommended for a minority of patients, specifically those with an IgE-mediated allergy to beta-lactams and considered in patients with known colonization with methicillin-resistant Staphylococcus aureus or at high risk for such. Vancomycin, however, has been overprescribed, has nephrotoxicity risk, and may be less effective due to its inferior coverage of methicillin-susceptible S.

View Article and Find Full Text PDF

Purpose: F-FDG PET/CT is an emerging technique for diagnosis of cardiac implantable electronic devices infection (CIEDI). Despite the improvements in transvenous lead extraction (TLE), long-term survival in patients with CIEDI is poor. The aim of the present study was to evaluate whether the extension of CIEDI at F-FDG PET/CT can improve prediction of survival after TLE.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!