Reliability and agreement on embryo assessment: 5 years of an external quality control programme.

Reprod Biomed Online

Unidad Reproducción, UGC de Laboratorio Clínico y UGC Obstetricia y Ginecología, HU Virgen de las Nieves, Instituto de Investigación Biosanitaria de Granada (ibs.granada), C/ Dr. Azpitarte, s/n, 18014 Granada, Spain; CEIFER Biobanco, Plaza Martínez Campos, 11, 18005 Granada, Spain; Departamento Anatomía y Embriología Humana, Facultad de Medicina, Universidad de Granada, Av. de la Investigación, 11, 18016 Granada, Spain.

Published: March 2018

An external quality-control programme for morphology-based embryo quality assessment, incorporating a standardized embryo grading scheme, was evaluated over a period of 5 years to determine levels of inter-observer reliability and agreement between practising clinical embryologists at IVF centres and the opinions of a panel of experts. Following Guidelines for Reporting Reliability and Agreement Studies, the Gwet index and proportion of positive (Ppos) and negative agreement were calculated. For embryo morphology assessment, a substantial degree of reliability was measured between the centres and the panel of experts (Gwet index: 0.76; 95% CI 0.70 to 0.84). The agreement was higher for good- versus poor-quality embryos. When multinucleation or vacuoles were observed, low levels of reliability were obtained (Ppos: 0.56 and 0.43, respectively). In blastocysts, the characteristic that presented the largest discrepancy was that related to the inner cell mass. In decisions about the final disposition of the embryo, reliability between centre and the panel of experts was moderate (Gwet index: 0.51; 95% CI 0.41 to 0.60). In conclusion, the ability of clinical embryologists to evaluate the presence of multinucleation and vacuoles in the early cleavage embryo, and to determine the category of the inner cell mass in blastocysts, needs to be improved.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.rbmo.2017.12.008DOI Listing

Publication Analysis

Top Keywords

reliability agreement
12
panel experts
12
clinical embryologists
8
multinucleation vacuoles
8
inner cell
8
cell mass
8
reliability
6
embryo
6
agreement embryo
4
embryo assessment
4

Similar Publications

The Diagnostic Utility of TRBC1 Immunohistochemistry in Mature T-Cell Lymphomas.

Mod Pathol

January 2025

Hematopathology Service, Department of Pathology and Laboratory Medicine, Memorial Sloan Kettering Cancer Center, New York, NY, USA. Electronic address:

T-cell clonality assessment constitutes an essential part of the diagnostic evaluation of suspected T-cell neoplasms. Recent advances in flow cytometry-based analysis of TCR β chain constant region 1 (TRBC1) have introduced an accurate method of assessment of T-cell clonality. Its broader applicability is constrained due to the requirement of viable cells.

View Article and Find Full Text PDF

Myocardial extracellular volume fraction (ECV) measured via MRI serves as a quantitative indicator of myocardial fibrosis. However, accurate measurement of ECV using MRI in the presence of AF is challenging. Meanwhile, CT could be a promising alternative tool for measuring ECV regardless of sinus rhythm or AF.

View Article and Find Full Text PDF

Gas-phase and water-mediated mechanisms for the OCS + OH reaction.

Phys Chem Chem Phys

January 2025

Departamento de Físico-Química, Instituto de Química - Universidade Federal da Bahia, Rua Barão de Jeremoabo, 147, Salvador, Bahia, 40170-115, Brazil.

We report a computational study of the gas-phase and water-mediated mechanisms for the oxidation of carbonyl sulfide (OCS) by the hydroxyl radical. To achieve reliable results, we employ a dual-level strategy within interpolated single-point energies (VTST-ISPE) at the CCSD(T)/aug-cc-pVTZ//M06-2X/aug-cc-pVTZ level of theory. In the gas-phase mechanism, we have determined the rate constants by kinetic Monte Carlo simulation in the interval of temperatures of 250-550 K.

View Article and Find Full Text PDF

Objectives: To assess the safety, reliability and acceptability of the modified incremental step test (MIST) supervised remotely via videoconferencing in adults with chronic respiratory disease.

Methods: Adults with chronic respiratory disease undertaking pulmonary rehabilitation were invited to undertake the MIST under two testing conditions: in-person supervision and remote supervision via video-conferencing. Test order was randomised.

View Article and Find Full Text PDF

Background: The Abbreviated Injury Scale (AIS) and Injury Severity Score (ISS) grade the severity of injuries and are useful for trauma audit and benchmarking. However, AIS coding is complex and requires specifically trained staff. A simple yet reliable scoring system is needed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!