Objectives: The current study evaluated the clinical usefulness of the gradient and spin-echo (GRASE) sequence with single breath-hold in 3.0 T magnetic resonance cholangiopancreatography (MRCP). We compared the acquisition time and image quality between GRASE and breath navigator-triggered 3D turbo spin echo (3D TSE).

Methods: We examined 54 consecutive patients who underwent MRCP with GRASE and 3D TSE. We compared the image acquisition time and contrast-to-noise ratio (CNR) between the common bile duct (CBD) and liver. Overall image quality, blurring, motion artifacts and CBD visibility were scored on a 4-point scale by two radiologists. Paired t-tests were used to compare the variables.

Results: The mean image acquisition time was 95 % shorter with the GRASE than with 3D TSE (GRASE: 20 s; 3D TSE: 6 min 27 s). The CNR of GRASE was significantly higher than that of 3D TSE (GRASE: 25.4 ± 13.9 vs. 3D TSE: 18.2 ± 9.6, p < 0.01). All qualitative scores for GRASE were significantly better than those for 3D TSE.

Conclusions: 3.0 T MRCP with GRASE sequence with single breath-hold significantly improved the CNR of CBD with a 95 % shorter acquisition time compared with conventional 3D MRCP with 3D TSE.

Key Points: • MRCP acquisition time was 95% shorter with GRASE than with 3D TSE. • Overall image quality of GRASE was significantly better than 3D TSE. • Pancreaticobiliary tree visibility with GRASE was better than that with 3D TSE.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-017-5240-yDOI Listing

Publication Analysis

Top Keywords

acquisition time
24
image quality
16
grase tse
16
grase
13
grase sequence
12
grase better
12
magnetic resonance
8
resonance cholangiopancreatography
8
time compared
8
sequence single
8

Similar Publications

Two-dimensional identification of lower limb gait features based on the variational modal decomposition of sEMG signal and convolutional neural network.

Gait Posture

December 2024

Engineering Research Center of the Ministry of Education for Intelligent Rehabilitation Equipment and Detection Technologies, Hebei University of Technology, Tianjin 300401, PR China; Hebei Key Laboratory of Robot Sensing and Human-robot Interaction, Hebei University of Technology, Tianjin 300401, PR China; School of Mechanical Engineering, Hebei University of Technology, Tianjin 300401, PR China. Electronic address:

Background: Gait feature recognition is crucial to improve the efficiency and coordination of exoskeleton assistance. The recognition methods based on surface electromyographic (sEMG) signals are popular. However, the recognition accuracy of these methods is poor due to ignoring the correlation of the time series of sEMG signals.

View Article and Find Full Text PDF

Risk analysis of cardiovascular toxicity in patients with lymphoma treated with CD19 CAR T cells.

J Transl Med

January 2025

Department of Hematology Oncology, Affiliated Hospital of Guizhou Medical University, No. 4 Bei Jing Road, Yunyan District, Guiyang, 550004, Guizhou, China.

Background: Anti-CD19 chimeric antigen receptor (CAR) T cell therapy is a common, yet highly efficient, cellular immunotherapy for lymphoma. However, many recent studies have reported on its cardiovascular (CV) toxicity. This study analyzes the cardiotoxicity of CD19 CAR T cell therapy in the treatment of lymphoma for providing a more valuable reference for clinicians.

View Article and Find Full Text PDF

Home Urine Dipstick Screening for Bladder and Kidney Cancer in High-Risk Populations in England: A Microsimulation Study of Long-Term Impact and Cost-Effectiveness.

Pharmacoeconomics

January 2025

Sheffield Centre for Health and Related Research (SCHARR), School of Medicine and Population Health, The University of Sheffield, Regent Court, 30 Regent Street, Sheffield, UK.

Background: Testing high-risk populations for non-visible haematuria may enable earlier detection of bladder cancer, potentially decreasing mortality. This research aimed to assess the cost-effectiveness of urine dipstick screening for bladder cancer in high-risk populations in England.

Methods:  A microsimulation model developed in R software was calibrated to national incidence data by age, sex and stage, and validated against mortality data.

View Article and Find Full Text PDF

Hand movements frequently occur with speech. The extent to which the memories that guide co-speech hand movements are tied to the speech they occur with is unclear. Here, we paired the acquisition of a new hand movement with speech.

View Article and Find Full Text PDF

Background: Multiparametric MRI (Mp-MRI) is a key tool to screen for Prostate Cancer (Pca) and Clinically Significant Prostate Cancer (CsPca). It primarily includes T2-Weighted imaging (T2w), diffusion-weighted imaging (DWI), and Dynamic Contrast-Enhanced imaging (DCE). Despite its improvements in CsPca screening, concerns about the cost-effectiveness of DCE persist due to its associated side effects, increased cost, longer acquisition time, and limitations in patients with poor kidney function.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!