The aim of this study was to evaluate the soft tissue thickness and marginal bone loss around dental implants with sloped micro-threaded shoulder (30° angle) in comparing with conventional design, inserted 30° degrees angulated in post extraction sockets and immediate loaded with temporary prosthesis simulating the all-on-four protocol. Six fox hound dogs received forty-eight post extraction dental implants with the different diameter and length (Medentika, Germany), but with different neck configurations. Two group of implants were inserted 1mm subcrestal [corrected]. Control group has a micro-threaded neck and the Test group has a sloped microthreaded neck. Immediate loading was applied using a constructed metallic structure. After three months, soft and hard tissue levels were assessed by histomorphometric analysis. The mean soft tissue thickness (STT) was 2.5 ± 0.2 mm for the Control group and 3.3 ± 0.3 mm for Test group ( = 0.036), meanwhile the mean marginal bone loss (MBL) was 1.53 ± 0.34 mm for Control group and, 1.62 ± 0.22 mm for Test group ( > 0.05). Within the limitations of this experimental model in dogs, the findings showed that dental implants with microthreaded and microthreaded sloped necks installed in immediate post extraction sites with immediate load, presented a comparable perimplant tissue behavior.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5793617PMC
http://dx.doi.org/10.3390/ma11010119DOI Listing

Publication Analysis

Top Keywords

dental implants
16
post extraction
12
control group
12
test group
12
histomorphometric analysis
8
soft tissue
8
tissue thickness
8
marginal bone
8
bone loss
8
group
7

Similar Publications

The aim of this study was to evaluate the mechanical properties and degree of conversion of a novel 3D-printing model resin and compare it to eight commercially available model resins. An experimental resin formulated by our proprietary resin technology along with DentaModel, NextDent 2, KeyModel Ultra, Rodin Model, Die and Model 2, DMR III, LCD Grey, and Grey Resin were used in this study. Parallelepiped specimens (2 × 2 × 25 mm, n = 5) were printed and measured for their flexural strength (FS), flexural modulus (FM), and modulus of resilience (MR) in accordance with ISO-4049.

View Article and Find Full Text PDF

Biosynthesis and Characterization of Silver Nanoparticles and Simvastatin Association in Titanium Biofilms.

Pharmaceuticals (Basel)

November 2024

Laboratório de Farmacologia de Antimicrobianos e Microbiologia, Faculdade de Ciências Farmacêuticas, Universidade Estadual de Campinas (UNICAMP), Campinas 13083-970, Brazil.

Introduction: Simvastatin is an antilipidemic drug that has already demonstrated antibacterial activities on oral and non-oral microorganisms. Silver nanoparticles also exhibit antimicrobial properties, particularly for coating implant surfaces. In this study, we evaluated the effects of combining simvastatin with silver nanoparticles on the formation and viability of biofilms consolidated on titanium discs.

View Article and Find Full Text PDF

Implant Surface Decontamination Methods That Can Impact Implant Wettability.

Materials (Basel)

December 2024

Department of Prosthodontics and Digital Technology, School of Dental Medicine, Stony Brook University, Stony Brook, NY 11794, USA.

This review addresses the effects of various decontamination methods on the wettability of titanium and zirconia dental implants. Despite extensive research on surface wettability, there is still a significant gap in understanding how different decontamination techniques impact the inherent wettability of these surfaces. Although the literature presents inconsistent findings on the efficacy of decontamination methods such as lasers, air-polishing, UV light, and chemical treatments, the reviewed studies suggest that decontamination alters in vitro hydrophilicity.

View Article and Find Full Text PDF

Exploring the Broad Spectrum of Titanium-Niobium Implants and Hydroxyapatite Coatings-A Review.

Materials (Basel)

December 2024

The Interdisciplinary Center for Dental Research and Development, Faculty of Dental Medicine, "Carol Davila" University of Medicine and Pharmacy, 19-21 Jean Louis Calderon Street, 020021 Bucharest, Romania.

Tooth loss replacement using dental implants is becoming more frequent. Traditional dental implant materials such as commercially pure titanium and titanium aluminum vanadium alloys have well-proven mechanical and biological properties. New titanium alloying metals such as niobium provide improved mechanical properties such as lower elastic modulus while displaying comparable or even better biocompatibility.

View Article and Find Full Text PDF

Development and Prevention of Biofilm on Cochlear Implants: A Systematic Review.

Medicina (Kaunas)

November 2024

1st Department of Pharmacology, School of Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.

Biofilm formation on cochlear implants (CIs) poses a major problem for surgeons, leading to a high incidence of explantation and revision surgery. Therefore, developing appropriate and cost-effective biofilm detection and prevention techniques is of the essence. In this systematic review, we sought to investigate the development of biofilm formation on CIs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!