Objectives: To investigate the potential protective effects of sesamol in an experimental cataract model.

Materials And Methods: Twenty-one Spraque Dawley rat pups were randomly assigned into three groups, seven rats in each. All the rats except for those in the control group were injected subcutaneously with a single dose of sodium selenite on postpartum day 9. On days 10-14, rats in the sham group were intraperitoneally administered 50 mg/kg/day saline solution, while rats in the sesamol group were given 50 mg/kg/day sesamol by the same route. Following cataract grading, the lenses and capsules were extracted and the mean levels of reduced glutathione (GSH), malondialdehyde (MDA), total antioxidant status (TAS) and total oxidant status (TOS) in lens supernatants were biochemically analyzed.

Results: The control group did not show any development of cataract. It was found that the mean cataract grade in the sesamol group was significantly lower than that of the sham group (p<0.05). The mean GSH level and TAS in the sesamol group were significantly higher than those of the sham group while the mean TOS and MDA level in the sesamol group were significantly lower than those of the sham group (p<0.05).

Conclusion: Our study shows that sesamol reduces TOS and MDA level and increases TAS and GSH level in the lens and inhibits cataract formation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5758764PMC
http://dx.doi.org/10.4274/tjo.42385DOI Listing

Publication Analysis

Top Keywords

experimental cataract
8
control group
8
sham group
8
sesamol group
8
group
6
cataract
5
protective sesamol
4
sesamol selenite-induced
4
selenite-induced experimental
4
cataract model
4

Similar Publications

Purpose: To describe a three-phase surgical approach for managing progressive visual decline in a patient with myopia magna and a history of epikeratophakia.

Methods: A 55-year-old woman with previous epikeratophakia surgery in both eyes experienced progressive visual deterioration. The three-phase approach included: (1) removal of the epikeratophakia lenticule, (2) cataract extraction with intraocular lens implantation, and (3) transepithelial topography-guided photorefractive keratectomy (trans-PRK).

View Article and Find Full Text PDF

Aim: The present study was conducted to determine the effect of non-pharmacological interventions before cataract surgery on preoperative anxiety.

Design: Systematic review and meta-analysis.

Methods: Five databases were systematically searched until 9 June, 2024.

View Article and Find Full Text PDF

Purpose: To assess the safety and efficacy of a modified suprachoroidal silicone tube (SST) shunt in patients with primary open-angle glaucoma (POAG) and pseudo-exfoliative glaucoma (PXG) in this experimental study.

Methods: In this single-center, retrospective longitudinal data analysis 66 eyes of 59 patients having POAG and PXG were included and treated with modified SST shunt in combination with cataract or as a stand-alone procedure. Pre- and postoperative intraocular pressure (IOP), best corrected visual acuity (BCVA), C/D ratio and ocular adverse events (AEs) were assessed in all participants.

View Article and Find Full Text PDF

Cataracts are significant causes of blindness, closely linked to prolonged hypercholesterolemia. While saffron has the potential for eye health, its effects on lens lesions remain understudied. This study aimed to investigate the effect of saffron on the lens changes in atherosclerotic-induced New Zealand white rabbits (NZWR).

View Article and Find Full Text PDF

Normalization of Retinal Birefringence Scanning Signals.

Sensors (Basel)

December 2024

Ophthalmic Instrumentation Development Lab, The Wilmer Eye Institute, The Johns Hopkins University School of Medicine, Wilmer 233, 600 N. Wolfe St., Baltimore, MD 21287, USA.

Signal amplitudes obtained from retinal scanning depend on numerous factors. Working with polarized light to interrogate the retina, large parts of which are birefringent, is even more prone to artifacts. This article demonstrates the necessity of using normalization when working with retinal birefringence scanning signals in polarization-sensitive ophthalmic instruments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!