Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Maintaining mechanical circulatory support (MCS) device patients in a specified therapeutic range for anticoagulation remains challenging. Subtherapeutic international normalized ratios (INRs) occur frequently while on warfarin therapy. An effective anticoagulant bridge strategy may improve the care of these patients. This retrospective review of MCS patients with subtherapeutic INRs compared an intravenous unfractionated heparin (UFH) strategy with a subcutaneous enoxaparin or fondaparinux strategy. Native thromboelastography (n-TEG) was used to evaluate anticoagulant effect with coagulation index (CI) as the primary outcome measure. Enoxaparin 0.5 mg/kg subcutaneously (SC) every 12 hours or fondaparinux 2.5-5 mg SC daily were compared with an initial UFH rate of 5 units/kg/hr and titrated to stated n-TEG goal range. The anticoagulant groups UFH, enoxaparin, and fondaparinux were found to be statistically similar with regard to frequency in n-TEG goal range, above range (hypercoagulability), or below range (hypocoagulability). Clinical outcomes were similar among groups with three gastrointestinal bleeds in UFH, one in enoxaparin, and one in fondaparinux groups. Device thrombosis occurred in one UFH patient, while UFH and fondaparinux groups had one ischemic cerebrovascular accident event each. These strategies provided comparable n-TEG results and clinical outcomes when compared with intravenous UFH. Low-dose enoxaparin or fondaparinux may provide an alternative anticoagulant bridging option in MCS patients presenting with subtherapeutic INR.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/MAT.0000000000000747 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!