A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Pilot Clinical Study of a Safe and Efficient Stool Management System in Patients With Fecal Incontinence. | LitMetric

Introduction: According to the Wound Ostomy Continence Nursing Society's Continence Committee, the incidence of fecal incontinence (FI) can occur from 18% to 37% in an acute care setting. A stool management system has been designed to manage FI in bedridden patients and has proven to be efficacious in wound management and prevention and infection control, provide safer patient outcomes, and enhance ease of nursing.

Objective: This study aims to evaluate the safety and efficacy of an intrarectal device intended to manage fecal incontinence in hospitalized bedridden patients through nonclinical and clinical testings.

Materials And Methods: An uncontrolled pilot evaluation in 20 patients was performed as part of a value-based purchasing evaluation at a tertiary hospital in Tucson, Arizona, to assess safety and efficacy in infection control and wound care. The company-provided engineering bench-top studies of insertion and withdrawal forces of the device versus existing intrarectal balloon catheters also were evaluated.

Results: The device has broader patient eligibility and potentially allows 3 times more FI patients to be managed safely. It has lower intrarectal pressures compared with indwelling balloon catheters.

Conclusions: This study, along with pilot clinical findings, suggests that this technology minimizes the pressure exerted on the rectal wall. There were significantly fewer forces against the anorectal mucosa compared with the cuff-based catheter during insertion, withdrawal, and accidental expulsion.

Download full-text PDF

Source

Publication Analysis

Top Keywords

fecal incontinence
12
pilot clinical
8
stool management
8
management system
8
bedridden patients
8
infection control
8
safety efficacy
8
insertion withdrawal
8
patients
5
clinical study
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!