A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Microfluidic Paper-based Analytical Device for Quantification of Lead Using Reaction Band-length for Identification of Bullet Hole and Its Potential for Estimating Firing Distance. | LitMetric

A low-cost and user-friendly microfluidic paper-based analytical device (μPAD) was developed for identification of bullet hole from gunshot residue (GSR) on cotton fabric target. The device (25 × 82 mm) is made of filter paper with a printed pattern consisting of a circular sample loading reservoir (6 mm i.d.), a circular waste reservoir (4 mm i.d.) and a straight flow channel (3 mm wide and 60 mm long). A sticker with a ruler scale in millimeters was mounted alongside the channel. The straight channel is first impregnated with rhodizonate and dried at ambient temperature. Tartrate extract of the target fabric is loaded on the sample reservoir. If Pb(II) ions are present in the extract, pink streak of Pb(II)-rhodizonate precipitate is formed as the sample solution flows from the reservoir along the channel. The length of the pink strip is employed to estimate the firing distance.

Download full-text PDF

Source
http://dx.doi.org/10.2116/analsci.34.83DOI Listing

Publication Analysis

Top Keywords

microfluidic paper-based
8
paper-based analytical
8
analytical device
8
identification bullet
8
bullet hole
8
firing distance
8
device quantification
4
quantification lead
4
lead reaction
4
reaction band-length
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!