A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A novel percutaneous achievement and maintenance of reduction and screw fixation for acute displaced scaphoid fractures: minimum two-year follow-up. | LitMetric

Purpose: The purpose of this study was to introduce a novel method of percutaneous achievement and maintenance of reduction for acute displaced scaphoid fractures and evaluate the feasibility of this method in treating acute displaced scaphoid fractures as well as explore its indications.

Methods: From February 2012 to March 2014, 15 patients with acute displaced scaphoid fractures were treated with our technique. Two Kirschner wires were used to achieve and maintain the reduction of the scaphoid fractures throughout the entire process of the traditional percutaneous screw fixation process. The following parameters including function scores according to modified Mayo wrist scoring system, range of motion (ROM) of the wrist, grip strength, pinch strength, healing time, time to return to work, and final outcomes were recorded.

Result: All patients were followed up with a mean period of 2.5 years (range, 2-3.5 years). All fractures healed with a mean of 9.3 weeks (range, 7-11.5 weeks). All patients returned to pre-injury level of activity within six weeks. The functional scores averaged 90.3 (range, 80-100). ROM of the wrist was equal to that of the contralateral side at three months postoperatively. Grip strength and pinch strength compared with contralateral were 98% and 92%, respectively. All were satisfied with the final outcomes.

Conclusions: Our technique is successfully performed in acute displaced scaphoid fractures resulting in shortened immobilization and prompt functional recovery. It broadens the indications of the percutaneous method, which means the advantages of the percutaneous method are maximally reserved whilst the drawbacks of open reduction were avoided.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00264-018-3758-5DOI Listing

Publication Analysis

Top Keywords

scaphoid fractures
24
acute displaced
20
displaced scaphoid
20
percutaneous achievement
8
achievement maintenance
8
maintenance reduction
8
screw fixation
8
rom wrist
8
grip strength
8
strength pinch
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!