Robust principal component analysis in optical micro-angiography.

Quant Imaging Med Surg

Department of Bioengineering, University of Washington, Seattle, WA, USA.

Published: December 2017

Background: Recent development of optical micro-angiography (OMAG) utilizes principal component analysis (PCA), where linear-regression filter is employed to separate static and blood flow signals within optical coherence tomography (OCT). While PCA is relatively simple and computationally efficient, the technique is sensitive to and easily skewed by outliers. In this paper, robust PCA (RPCA) is thus introduced to tackle this issue in traditional PCA.

Methods: We first provide brief theoretical background of PCA and RPCA in the context of OMAG where coherent (complex) OCT signals are utilized to contrast blood flow. We then compare PCA and RPCA on sets of 4D-OCT complex data (3 dimensions in space and 1 dimension in time), which are collected from microfluidic phantoms and nail-fold tissue.

Results: In phantom experiments, both analyses perform relatively well since there are little motion within our observation time window, albeit small tail-noise artifacts from PCA. In nail-fold experiment, PCA suffers from tissue motion, from which RPCA does not seem to be affected. Results from RPCA also show enhancements of other dynamic signals, which are likely from the intercellular fluid. This unwanted result is yet to be proven useful for clinical applications.

Conclusions: Traditional PCA method employs linear-regression filter and is sensitive to outliers (tail-noise and motion artifacts). RPCA method is robust against outliers, but is currently computationally expensive.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5756790PMC
http://dx.doi.org/10.21037/qims.2017.12.05DOI Listing

Publication Analysis

Top Keywords

pca rpca
12
principal component
8
component analysis
8
optical micro-angiography
8
pca
8
linear-regression filter
8
blood flow
8
rpca
6
robust principal
4
analysis optical
4

Similar Publications

Objective: Robotic-assisted total knee arthroplasty (TKA) is a novel orthopedic technique. The workflow of robotic-assisted TKA is quite different from that of traditional manual TKA and may result incompletely different resection parameters. Understanding these parameters may help surgeons better perform robotic-assisted TKA.

View Article and Find Full Text PDF
Article Synopsis
  • Background subtraction in X-ray coronary angiograms (XCA) enhances the diagnosis of coronary vessel diseases but is challenging due to complex background dynamics.
  • The proposed OTS-RPCA method uses robust PCA for background removal, employing techniques like morphological closing and tree-structured norms to improve vessel coherence and reduce noise.
  • Evaluated on real and synthetic datasets, the method outperformed seven existing techniques, yielding superior contrast and structural preservation of coronary vessels, as indicated by high CNR and SSIM values.
View Article and Find Full Text PDF

X-ray coronary angiograms (XCA) are widely used in diagnosing and treating cardiovascular diseases. Various structures with independent motion patterns in the background of XCA images and limitations in the dose of injected contrast agent have resulted in low-contrast XCA images. Background subtraction methods have been developed to enhance the visibility and contrast of coronary vessels in XCA sequences, consequently reducing the requirement for excessive contrast agent injections.

View Article and Find Full Text PDF

It is well known that different muscles of yak exhibit distinctive characteristics, such as muscle fibers and metabolomic profiles. We hypothesized that different muscles could alter the flavor profile of yak jerky. Therefore, the objective of this study was to investigate the differences in flavor profiles of yak jerky produced by (LT), (TB) and (BF) through electronic nose (E-nose), electronic tongue (E-tongue), gas chromatography-mass spectrometry (GC-MS) and gas chromatography-ion mobility spectrometry (GC-IMS).

View Article and Find Full Text PDF

Robust PCA with and Norms: A Novel Method for Low-Quality Retinal Image Enhancement.

J Imaging

June 2024

Computer Science and Engineering, School of Computing and Augmented Intelligence, Arizona State University, Phoenix, AZ 85287-8809, USA.

Nonmydriatic retinal fundus images often suffer from quality issues and artifacts due to ocular or systemic comorbidities, leading to potential inaccuracies in clinical diagnoses. In recent times, deep learning methods have been widely employed to improve retinal image quality. However, these methods often require large datasets and lack robustness in clinical settings.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!