Impact of iterative reconstruction vs. filtered back projection on image quality in 320-slice CT coronary angiography: Insights from the CORE320 multicenter study.

Medicine (Baltimore)

Department of Medicine/Cardiology Division, Johns Hopkins University, Baltimore, MD Department of Medicine/Cardiology Division, Suez Canal University, Ismailia, Egypt Department of Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany Toshiba Medical Systems, Otawara, Minato-Ku, Tokyo, Japan Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD Joint Department of Medical Imaging, Toronto General Hospital, Toronto, Canada Beth Israel Deaconess Medical Center, Harvard University, Boston, MA.

Published: December 2017

Iterative reconstruction has been shown to reduce image noise compared with traditional filtered back projection with quantum denoising software (FBP/QDS+) in CT imaging but few comparisons have been made in the same patients without the influence of interindividual factors. The objective of this study was to investigate the impact of adaptive iterative dose reduction in 3-dimensional (AIDR 3D) and FBP/QDS+-based image reconstruction on image quality in the same patients.We randomly selected 100 patients enrolled in the coronary evaluation using 320-slice CT study who underwent CT coronary angiography using prospectively electrocardiogram triggered image acquisition with a 320-detector scanner. Both FBP/QDS+ and AIDR 3D reconstructions were performed using original data. Studies were blindly analyzed for image quality by measuring the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Image quality was assessed qualitatively using a 4-point scale.Median age was 63 years (interquartile range [IQR]: 56-71) and 72% were men, median body mass index 27 (IQR: 24-30) and median calcium score 222 (IQR: 11-644). For all regions of interest, mean image noise was lower for AIDR 3D vs. FBP/QDS+ (31.69 vs. 34.37, P ≤ .001). SNR and CNR were significantly higher for AIDR 3D vs. FBP/QDS+ (16.28 vs. 14.64, P < .001 and 19.21 vs. 17.06, P < .001, respectively). Subjective (qualitative) image quality scores were better using AIDR 3D vs. FBP/QDS+ with means of 1.6 and 1.74, respectively (P ≤ .001).Assessed in the same individuals, iterative reconstruction decreased image noise and raised SNR/CNR as well as subjective image quality scores compared with traditional FBP/QDS+ in 320-slice CT coronary angiography at standard radiation doses.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5728730PMC
http://dx.doi.org/10.1097/MD.0000000000008452DOI Listing

Publication Analysis

Top Keywords

image quality
16
iterative reconstruction
8
filtered projection
8
image
8
coronary angiography
8
image noise
8
aidr fbp/qds+
8
impact iterative
4
reconstruction filtered
4
projection image
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!