Recently, microwave resonance technology (MRT) sensor systems operating at four resonances instead of a single resonance frequency were established as a process analytical technology (PAT) tool for moisture monitoring. The additional resonance frequencies extend the technologies' possible application range in pharmaceutical production processes remarkably towards higher moisture contents. In the present study, a novel multi-resonance MRT sensor was installed in a bottom-tangential-spray fluidized bed granulator in order to provide a proof-of-concept of the recently introduced technology in industrial pilot-scale equipment. The mounting position within the granulator was optimized to allow faster measurements and thereby even tighter process control. As the amount of data provided by using novel MRT sensor systems has increased manifold by the additional resonance frequencies and the accelerated measurement rate, it permitted to investigate the benefit of more sophisticated evaluation methods instead of the simple linear regression which is used in established single-resonance systems. Therefore, models for moisture prediction based on multiple linear regression (MLR), principal component regression (PCR), and partial least squares regression (PLS) were built and assessed. Correlation was strong (all R > 0.988) and predictive abilities were rather acceptable (all RMSE ≤0.5%) for all models over the whole granulation process up to 16% residual moisture. While PCR provided best predictive abilities, MLR proofed as a simple and valuable alternative without the need of chemometric data evaluation.

Download full-text PDF

Source
http://dx.doi.org/10.1080/03639045.2018.1425427DOI Listing

Publication Analysis

Top Keywords

mrt sensor
12
moisture monitoring
8
fluidized bed
8
sensor systems
8
additional resonance
8
resonance frequencies
8
linear regression
8
predictive abilities
8
moisture
5
laboratory- pilot-scale
4

Similar Publications

Modeling engagement with a digital behavior change intervention (HeartSteps II): An exploratory system identification approach.

J Biomed Inform

October 2024

Control Systems Engineering Laboratory, School for Engineering of Matter, Transport, Energy, Arizona State University, Tempe, AZ 85287, United States.

Objective: Digital behavior change interventions (DBCIs) are feasibly effective tools for addressing physical activity. However, in-depth understanding of participants' long-term engagement with DBCIs remains sparse. Since the effectiveness of DBCIs to impact behavior change depends, in part, upon participant engagement, there is a need to better understand engagement as a dynamic process in response to an individual's ever-changing biological, psychological, social, and environmental context.

View Article and Find Full Text PDF

Use of rumination time in health risk assessment of prepartum dairy cows.

J Dairy Sci

October 2024

Department of Animal Biosciences, University of Guelph, Guelph, ON, Canada N1G 2W1. Electronic address:

The objectives of this observational cohort study were to evaluate the associations of rumination time (RT) in the last week of pregnancy with transition cow metabolism, inflammation, health, and subsequent milk production, reproduction, and culling. Pregnant nulliparous (n = 199) and parous (n = 337) cows were enrolled 21 d before expected calving. Rumination time and physical activity were monitored automatically by sensors from d -21 to 15 relative to calving.

View Article and Find Full Text PDF

Quantum state readout is a key requirement for a successful qubit platform. In this work, we demonstrate a high-fidelity quantum state readout of a V2 center nuclear spin based on a repetitive readout technique. We demonstrate up to 99.

View Article and Find Full Text PDF

Nuclear spins with hyperfine coupling to single electron spins are highly valuable quantum bits. Here we probe and characterize the particularly rich nuclear-spin environment around single silicon vacancy color centers (V2) in 4H-SiC. By using the electron spin-3/2 qudit as a four level sensor, we identify several sets of ^{29}Si and ^{13}C nuclear spins through their hyperfine interaction.

View Article and Find Full Text PDF

As populations and temperatures of urban areas swell, more people face extreme heat and are at increasing risk of adverse health outcomes. Radiation accounts for much of human heat exposure but is rarely used as heat metric due to a lack of cost-effective and accurate sensors. To this end, we fuse the concepts of a three-globe radiometer-anemometer with a cylindrical human body shape representation, which is more realistic than a spherical representation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!