Ideal parameters for femto-second laser-assisted anterior capsulotomy: Animal studies.

PLoS One

Department of Ophthalmology and Catholic Institute for Visual Science, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.

Published: February 2018

In femtosecond laser-assisted cataract surgery, the parameter such as horizontal spot spacing and energy level can be adjusted. Although there have been several studies reported on various laser systems, showing the effects of varying energy levels and horizontal spot spacing on lens capsulotomy cut edges, none have been reported on the Catalys laser system (Abbott Medical Optics, Inc., Santa Ana, CA). The aim of this study is to evaluate, using scanning electron microscopy (SEM), the quality of the cut edges of the laser lens capsulotomy obtained using the Catalys Laser System, using different horizontal spot spacing and energy levels, and to determine the ideal parameters based on SEM results. Fifty rabbit capsulorhexis specimens from a femtosecond laser with different spot spacing and energy settings were divided into five groups randomly. Spot spacing was 3 um and laser pulse energy was 4 uJ in group 1. The respective values were 5 um and 2 uJ in group 2, 5 um and 4 uJ in group 3, 5 um and 6 uJ in group 4, and 7 um and 4 uJ in group 5. All samples were evaluated using SEM to compare the number of tags per capsulotomy and the laser emission time. Group 1 had a significantly lower tag formation than groups 3 and 5 (P = 0.042 and 0.021, respectively). Although the laser emission time increased about 1.5 sec as the spot spacing increased from 3 to 7 um, the quality of the cut was smoother in group 1 because of overlapping effect of photodisruption cavities. There was no significant difference between groups 2, 3 and 4 at different laser energy settings. In an ex-vivo study, samples from an energy setting of 10 uJ showed increased irregularity and damage. The degree of irregularity was higher at increasing spot spacing and laser energy settings, with abundant tag formation. Dense spot spacing with low-energy settings provide a better cut quality, which is probably correlated with the reduction in anterior capsular tear complications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5755902PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0190858PLOS

Publication Analysis

Top Keywords

spot spacing
32
horizontal spot
12
spacing energy
12
energy settings
12
group group
12
laser
10
ideal parameters
8
spot
8
spacing
8
energy
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!