The occurrence of Malassezia spp. bloodstream infections (BSIs) in neonatal intensive care unit was evaluated by using pediatric Isolator, BacT/Alert systems and central venous catheter (CVC) culture. The efficacy of BacT/Alert system in detecting Malassezia was assessed by conventional procedures, culturing 1 ml of bottle content before incubation and by studying the survival of Malassezia spp. strains in BacT/Alert bottles. Of the 492 neonates enrolled, blood was collected by pediatric Isolator (290 patients; group I) or by BacT/Alert bottles (202 patients; group II). The survival of Malassezia furfur and Malassezia pachydermatis in BacT/Alert bottles was evaluated by culturing the inoculum suspension (from 106 to 10 colony-forming units, cfu/ml) and assessing the cfu/ml for 15 days. In total, 15 Malassezia BSIs were detected, of which six (2.1%) from both blood and CVC culture in Dixon agar (DixA) in patients belong to group I (blood collected by paediatric Isolator tube) and nine (4.4%) only from CVC culture in DixA in patients of group II (blood collected by BacT/Alert bottle). Only one patient (0.5%) from group II scored positive for M. furfur also by culturing in DixA 1 ml blood content of BacT/Alert bottle before incubation in BacT/Alert system.M. furfur population size in BacT/Alert bottles decreased during the incubation time, whereas that of M. pachydermatis increased. The BacT/Alert system detected M. pachydermatis even at very low concentration (i.e., 10 cfu/ml) but not any positive blood culture for M. furfur. For a correct diagnosis of Malassezia furfur BSI, the blood should be culture in lipid-enriched fungal medium, and the BacT/Alert system implemented by adding lipid substrates to increase the method sensibility. Finally, CVC cultures on lipid-supplemented media may be proposed as a routine procedure to diagnose the Malassezia fungemia.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/mmy/myx122 | DOI Listing |
Transfusion
December 2024
Transfusional Medicine Group, Vall d'Hebron Research Institute-Autonomous University of Barcelona (VHIR-UAB), Barcelona, Spain.
Background: Umbilical cord blood (CB) units stored in banks are an important source of hematopoietic stem cells for transplantation and other cell therapies. New applications, such as their use in transfusions, require rapid quality release as cord blood red blood cells (CB-RBC) have a shorter shelf life.
Study Design And Methods: This project aims to investigate the most prevalent microbial contaminants in CB preparations and validate a rapid sterility testing strategy for CB-RBC based on an automated system (BACT/ALERT®) in tandem with a molecular assay (real-time PCR) capable of detecting at least 100 CFU/mL of Cutibacterium acnes in CB-RBC to accelerate the detection of the most common slow-growing bacteria.
Microbiol Spectr
November 2024
Department of Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, China.
Bloodstream infections (BSI) pose significant threats to patient health, necessitating timely and accurate diagnostics to reduce mortality and morbidity. This study aimed to evaluate the clinical performance of the BacT/ALERT VIRTUO blood culture system with FANPlus bottles compared to the BACTEC FX400 system in detecting bloodstream pathogens. A total of 1,772 blood specimens were collected from various hospital wards.
View Article and Find Full Text PDFIndian J Med Microbiol
November 2024
Istanbul University-Cerrahpasa, Cerrahpasa School of Medicine, Department of Medical Microbiology, Istanbul, Turkey. Electronic address:
Purpose: In our study, we aimed to compare the performance of the BacT/Alert 3D (bioMerieux, France) system, which is currently used in our laboratory, and the Autobio BC (Autobio, China) system, which was newly introduced in our country, using standard and clinical isolates.
Methods: Bacterial suspension was prepared by two technicians on the same day and three consecutive days from five different standard strains with 0.5 McFarland turbidity, then serial dilution to a final concentration was adjusted and was simultaneously inoculated in aerobic blood culture bottles.
Acta Clin Belg
October 2024
Department of Medical Microbiology, Ghent University Hospital, Ghent, Belgium.
Introduction: To speed up antimicrobial susceptibility testing (AST), the European Committee on Antimicrobial Susceptibility Testing (EUCAST) proposed rapid AST (RAST), a disk diffusion method to be read after 4, 6 and 8 hours of incubation. We investigated the feasibility of implementation of RAST in a non-automated lab setting.
Materials & Methods: To this end, reference strains as well as a variety of clinical and resistant strains were used to spike sterile hemocultures (BioMérieux BACT/ALERT 3D® and Becton Dickinson BACTEC FX® systems), followed by RAST in comparison to classical long-incubation AST.
Transfus Apher Sci
December 2024
Department of Pathology and Laboratory Medicine, Aga Khan University, Karachi, Pakistan. Electronic address:
Background: Transfusion of bacterially contaminated platelets may cause life threatening sepsis in the recipients. Cost of platelet screening is a major challenge for low middle income countries (LMICs). In this study, we evaluated the frequency of bacterial contamination in the platelet units (PUs) and the outcome of transfusing such platelets to the patients in a single institute at Pakistan.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!