Double-inlet left ventricle (DILV) is a congenital heart disease that only a single left ventricle and a rudimentary right ventricle are developed. Because of lack of anatomic landmark, interpretation of Tl myocardial perfusion imaging in DILV is essentially challenging for unusual anomaly. We report the case of a 44-year-old woman with DILV who presented exertional dyspnea and tachycardia and underwent Tl SPECT. The anatomic characteristics of cardiac Tl SPECT are correlated with MRI. To obtain accurate interpretation in DILV, it is absolutely necessary to realize the anatomy relationship between perfusion imaging and anatomic imaging such as CT or MRI.

Download full-text PDF

Source
http://dx.doi.org/10.1097/RLU.0000000000001961DOI Listing

Publication Analysis

Top Keywords

perfusion imaging
12
left ventricle
12
myocardial perfusion
8
double-inlet left
8
201tl myocardial
4
imaging
4
imaging case
4
case double-inlet
4
ventricle
4
ventricle correlate
4

Similar Publications

Diabetic microvascular dysfunction is evidenced by disrupted endothelial cell junctions and increased microvascular permeability. However, effective strategies against these injuries remain scarce. In this study, the type 2 diabetes mouse model was established by high-fat diet combined with streptozotocin injection in Rnd3 endothelial- specific transgenic and knockout mice.

View Article and Find Full Text PDF

Hepatopulmonary syndrome (HPS) is a rare pulmonary vascular complication of chronic liver disease characterized by dilatation of pulmonary capillaries leading to vascular shunting and systemic hypoxemia. Diagnosis of HPS requires documentation of intrapulmonary vasodilation (IPVD), the two most common imaging studies performed for the detection of IPVD include transthoracic contrast echocardiography (TTCE) and 99m-Tc-macroaggregated albumin scintigraphy (99mTc-MAA scan). TTCE has high sensitivity and thus, is the preferred initial investigation, while 99mTc-MAA scan is highly specific and plays an adjuvant role in diagnosis.

View Article and Find Full Text PDF

Adenosine is extensively utilized in myocardial stress perfusion imaging for the detection and risk stratification of coronary artery disease. It has a well-established safety profile. The majority of the undesirable effects experienced during adenosine infusion are transient (owing to its brief half-life of ~10 s) and arise from the stimulation of receptors in the atrio-ventricular (AV) node (AV block) and bronchial smooth muscles (bronchospasm).

View Article and Find Full Text PDF

Purposes: The objective was to evaluate the accuracy of a novel CT dynamic angiographic imaging (CT-DAI) algorithm for rapid fractional flow reserve (FFR) measurement in patients with coronary artery disease (CAD).

Materials And Methods: This retrospective study included 14 patients (age 58.5 ± 10.

View Article and Find Full Text PDF

Background: Cardiovascular diseases (CVDs) continue to be the world's greatest cause of death. To evaluate heart function and diagnose coronary artery disease (CAD), myocardial perfusion imaging (MPI) has become essential. Artificial intelligence (AI) methods have been incorporated into diagnostic methods such as MPI to improve patient outcomes in recent years.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!