Objective: We purpose a novel factor analysis method based on kinetic cluster and α-divergence measure for extracting the blood input function and the time-activity curve of the regional tissue from dynamic myocardial positron emission computed tomography(PET) images.

Methods: Dynamic PET images were decomposed into initial factors and factor images by minimizing the α-divergence between the factor model and actual image data. The kinetic clustering as a priori constraint was then incorporated into the model to solve the nonuniqueness problem, and the tissue time-activity curves and the tissue space distributions with physiological significance were generated.

Results: The model was applied to the 82RbPET myocardial perfusion simulation data and compared with the traditional model-based least squares measure and the minimal spatial overlap constraint. The experimental results showed that the proposed model performed better than the traditional model in terms of both accuracy and sensitivity.

Conclusion: This method can select the optimal measure by α value, and incorporate the prior information of the kinetic clustering of PET image pixels to obtain the accurate time-activity curves of the tissue, which has shown good performance in visual evaluation and quantitative evaluation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6744016PMC
http://dx.doi.org/10.3969/j.issn.1673-4254.2017.12.03DOI Listing

Publication Analysis

Top Keywords

dynamic myocardial
8
kinetic clustering
8
time-activity curves
8
curves tissue
8
model
5
[kinetic cluster
4
cluster α-divergence-based
4
α-divergence-based dynamic
4
myocardial factorial
4
factorial analysis
4

Similar Publications

The study was designed to investigate the pattern of intraventricular Hemo-Dynamic Forces (HDF) and myocardial performance during exercise in Elite Cyclists (EC). Transthoracic stress echocardiography was performed on nineteen EC and thirteen age-matched sedentary controls (SC) at three incremental exercise intensities based on Heart Rate Reserve (HRR). Left Ventricular (LV) HDF were computed from echocardiography long-axis data sets using a novel technique based on endocardial boundary tracking, both in apex-base and latero-septal directions.

View Article and Find Full Text PDF

Dynamic positron emission tomography (PET) can be used to non-invasively estimate the blood flow of different organs via compartmental modeling. Out of different PET tracers, water labeled with the radioactive O isotope of oxygen (half-life of 2.04 min) is freely diffusable, and therefore, very well-suited for blood flow quantification.

View Article and Find Full Text PDF

Imaging Carotid Plaque Burden in Living Mice via Hybrid Semiconducting Polymer Nanoparticles-Based Near-Infrared-II Fluorescence and Magnetic Resonance Imaging.

Research (Wash D C)

July 2023

State Key Laboratory for Chemo/ Bio-Sensing and Chemometrics, College of Chemistry and Chemical Engineering, Engineering, Hunan University, Changsha 410082, China.

The majority of atherothrombotic events (e.g., cerebral or myocardial infarction) often occur as a result of plaque rupture or erosion in the carotid, and thereby it is urgent to assess plaque vulnerability and predict adverse cerebrovascular events.

View Article and Find Full Text PDF

Introduction: In patients with acute myocardial infarction and cardiogenic shock (AMICS), the intra-aortic balloon pump (IABP) remains the most commonly used form of mechanical circulatory support (MCS). However, information on the characteristics of non-responders is limited. This study evaluated the risk factors associated with 30-day mortality in a cohort of patients with AMICS, on IABP support.

View Article and Find Full Text PDF

Near-Field Clutter Mitigation in Speckle Tracking Echocardiography.

Ultrasound Med Biol

January 2025

Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong; Biomedical Engineering Programme, The University of Hong Kong, Hong Kong. Electronic address:

Objective: Near-field (NF) clutter filters are critical for unveiling true myocardial structure and dynamics. Randomized singular value decomposition (rSVD) stands out for its proven computational efficiency and robustness. This study investigates the effect of rSVD-based NF clutter filtering on myocardial motion estimation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!