A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Qualitative assessment of extractables from single-use components and the impact of reference standard selection. | LitMetric

The advent of single-use bioprocess systems used for the delivery, storage or manufacture of biopharmaceuticals has introduced a new potential source for extractables and leachables (E&L) as these systems are comprised of polymeric materials. Several industry working groups, the FDA and USP have issued guidance and draft guidance on E&L analyses for a variety of applications. These documents typically indicate that mass spectrometry should be applied for discovery of E&L's but provide little guidance as to the exact analytical methodology which should be used. We investigated the extractable profiles of a model single-use bioprocessing system consisting of a single-use bioprocess bag, connector tubing, and a hydrophilic disk filter including filter housing. Extractions were performed in water, ethanol, ethanol/water (50:50) and saline solutions. Extracts were analyzed using a stepwise analytical methodology including a variety of screening and mass spectrometry methods We then used this model system to demonstrate the use of recursive feature finding to automatically detect unique extractables followed by statistical filtering to focus on differentially present extractables which were above the analytical evaluation threshold (AET). We further show the significant affects of standard selection on the number of compounds determined to be above AET when reducing liquid chromatography-mass spectrometry (LC/MS) data. A relative response factor database consisting of 14 structurally diverse commercially available polymer additives was used to arrive at an LC/MS identification threshold. The results of this study demonstrate that significant care should be taken when selecting standards for LC/MS analysis to avoid under reporting of extractables and leachables.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2017.12.029DOI Listing

Publication Analysis

Top Keywords

standard selection
8
single-use bioprocess
8
extractables leachables
8
mass spectrometry
8
analytical methodology
8
extractables
5
qualitative assessment
4
assessment extractables
4
single-use
4
extractables single-use
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!