Degradation of Poly(ε-caprolactone) and bio-interactions with mouse bone marrow mesenchymal stem cells.

Colloids Surf B Biointerfaces

Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Poojapura, Thiruvananthapuram 695 012, Kerala, India. Electronic address:

Published: March 2018

Bio-inspired scaffolds in bone tissue engineering using multipotential mesenchymal stem cells grow at a rapid rate found its successful use in orthopedic injury treatment. Poly(ε-caprolactone)/PCL is widely used in medical devices, tissue engineering, and drug delivery systems. Most desirable property of biodegradable polymer to be employed in medical application is synchronization of degradation with functional tissue regeneration. Limited studies have incorporated the degradation kinetics and implication of degradation products of pure unmodified PCL. The present study analyzes short term in vitro degradation profile of PCL films in physiological condition. The study reports weight loss, changes in molecular weight distribution and morphological variation in PCL thin film over a period of 90-day degradation. When the degradable material is in contact with host tissue, there exists robust and dynamic microenvironment controlling the cell functionality. To comprehend the biocompatibility aspects of polymer material, the study considered mouse bone marrow mesenchymal stem cells (BMSCs) as model system mimicking in vivo. There was no indication of toxicity revealed with MTT, LDH leakage, direct contact assay and clonogenic assay. Absence of oxidative stress and apoptosis denotes BMSCs functional integrity sustained upon exposure to PCL degradation products. Cell cycle analysis and DNA ladder assay confirmed cell survival and genomic stability. The study revealed that the topography of pure unmodified PCL surface is suitable for cell adhesion. It was also observed that the viability of differentiated cells (osteoblasts) was maintained in presence of PCL extract. Furthermore, polymer and its degradation products were proved to be hemocompatible. These results synergistically suggest that pure unmodified PCL and its degradation products are non-toxic at molecular level.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.colsurfb.2017.12.039DOI Listing

Publication Analysis

Top Keywords

degradation products
16
mesenchymal stem
12
stem cells
12
pure unmodified
12
unmodified pcl
12
degradation
9
mouse bone
8
bone marrow
8
marrow mesenchymal
8
tissue engineering
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!