Objective: To establish whether the round window approach (RWA) leads to less vestibular dysfunction and dizziness than the standard cochleostomy approach (SCA) during cochlear implant (CI) surgery, as assessed using the video head impulse test (vHIT).Additionally, objective findings were compared with the subjective dizziness perceived by the patient.
Study Design: Double blinded, clinical randomized trial.
Setting: University Hospital.
Patients: Fifty-two ears from 46 patients were included. Inclusion criterion was a gain value more than 0.50.
Intervention: Patients were randomized to the RWA or the SCA. Evaluation with the vHIT was performed before surgery, 1 day after surgery, and 1 month after surgery. Subjective dizziness was measured using a visual analogue scale (VAS) and the dizziness handicap inventory (DHI).
Main Outcome Measures: Gain values and the incidence of catch-up saccades.
Results: Three out of 23 patients in the SCA group experienced catch-up saccades compared with no patients in the RWA group, indicating the occurrence of objective vestibular dysfunction after CI surgery; the difference was not statistically significant. The VAS increased in both groups the day after surgery. The difference between the groups was not statistically significant. No statistically significant changes in the gain value or the DHI score could were observed between the two groups.
Conclusion: No statistically significant difference between the cochleostomy approach and the round window approach using the vHIT and subjective dizziness perceived by the patient was found.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5821484 | PMC |
http://dx.doi.org/10.1097/MAO.0000000000001695 | DOI Listing |
Otol Neurotol
January 2025
Department of Otolaryngology, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien, Taiwan.
Hypothesis: Extracochlear electric-acoustic stimulation (EAS) between the round window membrane and the basal part of the cochlear bone exhibits distinct auditory brainstem response (ABR) characteristics.
Background: The use of EAS in individuals with residual hearing is becoming increasingly common in clinical settings. Ongoing research has explored the characteristics of EAS-induced responses in hearing cochleae.
Front Neurol
December 2024
Department of Otorhinolaryngology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
Objectives: Multiple studies have described the onset and variable incidence of postoperative acute vertigo following cochlear implant (CI) surgery. However, postoperative imaging has not yet been specifically evaluated with special focus on vertigo. The aim of this study is to assess the incidence and causes of new-onset, acute postoperative vertigo following CI surgery using cone beam computed tomography (CBCT).
View Article and Find Full Text PDFTissue Cell
December 2024
ENT Department, Faculty of Medicine, Suez Canal University, Ismailia, Egypt. Electronic address:
Background: Sensorineural hearing loss (SNHL) is the most common sensory deficit worldwide. Current solutions for SNHL, including hearing aids, cochlear implants, and hearing assistive devices, do not provide consistent results and fail to address the underlying pathology of hair cell and ganglion cell damage. Stem cell therapy is a cornerstone in regenerative medicine.
View Article and Find Full Text PDFEur Arch Otorhinolaryngol
January 2025
Department of Radiology, Istanbul Training and Research Hospital, University of Health Sciences, Istanbul, Turkey.
Purpose: Cochlear implantation (CI) surgery is essential for restoring hearing in individuals with severe sensorineural hearing loss. Accurate placement of the electrode within the cochlea is essential for successful auditory outcomes and minimizing complications. This study aims to analyze the relationship between the round window niche (RWN) alignment, its visibility during surgery, and the impact on surgical techniques and outcomes.
View Article and Find Full Text PDFEur Radiol Exp
January 2025
Guilloz Imaging Department, Central Hospital, University Hospital Center of Nancy, 29 Avenue du Marechal de Lattre de Tassigny, 54000, Nancy, France.
Background: We evaluated the accuracy of magnetic resonance imaging (MRI) computed tomography (CT)-like sequences compared to normal-resolution CT (NR-CT) and super-high-resolution CT (SHR-CT) for planning of cochlear implantation.
Methods: Six cadaveric temporal bone specimens were used. 3-T MRI scans were performed using radial volumetric interpolated breath-hold (STARVIBE), pointwise-encoding time reduction with radial acquisition (PETRA), and ultrashort time of echo (UTE) sequences.