This case study describes the successful percutaneous transcatheter retrieval of an embolized Amplatzer occluder device using the "waist capture technique" in a patient with an atrial septal defect. This technique allowed for stability of the Amplatzer device, compression of the atrial discs for easier removal, prevention of further embolization, and minimal injury to vasculature during device retrieval. This novel and effective technique can be used safely for the retrieval of Amplatzer devices in the venous system.

Download full-text PDF

Source
http://dx.doi.org/10.1536/ihj.17-227DOI Listing

Publication Analysis

Top Keywords

transcatheter retrieval
8
retrieval embolized
8
atrial septal
8
septal defect
8
occluder device
8
embolized atrial
4
defect occluder
4
device
4
device waist
4
waist capture
4

Similar Publications

According to current guidelines, patients with heart valve disease should be followed by Heart Valve Clinics (HVCs). Regular quality analysis is a major prerequisite of an HVC's program, but few data have been reported so far. We retrospectively collected patients with isolated, native aortic valve stenosis who had been visited in our HVC at least once between 2021 and 2024.

View Article and Find Full Text PDF

Background: The transcatheter edge-to-edge repair (TEER) technique, facilitated by the MitraClip device, is a minimally invasive intervention designed for high-risk patients with mitral regurgitation (MR). This study conducts a retrospective analysis of death events associated with MitraClip implantation over a ten-year decade, utilizing data from the FDA's Manufacturer and User Facility Device Experience (MAUDE) database to evaluate trends in safety outcomes.

Methods: A comprehensive search of the publicly accessible MAUDE database was conducted to retrieve reports of deaths and injuries related to MitraClip implantation from October 2013 to September 2023.

View Article and Find Full Text PDF

Introduction: The docking button of the Aveir leadless pacemaker (LP) is occasionally difficult to access due to its inappropriate position in the right ventricle (RV).

Methods And Results: We report a case where the Aveir LP was successfully retrieved by releasing the wedged docking button in the inferior wall of the RV using a loop wire technique.

Conclusion: The loop wire technique may be useful to change the position of the Aveir LP.

View Article and Find Full Text PDF

Aims: Secondary mitral regurgitation (SMR) and tricuspid regurgitation (TR) are the most common valvular heart diseases in patients with heart failure (HF). Transcatheter edge-to-edge repair (TEER) devices designed for treating MR and TR have been successfully tested in randomized controlled trials, but methodological issues have often challenged their interpretation. This manuscript aimed to provide an overview of TEER registries on SMR and TR in HF, highlighting their key features, describing clinical characteristics and outcomes of patients receiving these devices, and exploring the available data limitations.

View Article and Find Full Text PDF

Transcatheter aortic valve replacement (TAVR) is a common treatment for severe aortic stenosis (AS), but it carries the risk of severe complications, including device embolization. We present a case of a TAVR valve embolization into the left ventricular outflow tract (LVOT), diagnosed with transesophageal echocardiography (TEE) shortly after device deployment. The dislodged valve was successfully retrieved from the LVOT into the aorta, flattened, and stabilized with a thoracic endovascular aneurysm repair (TEVAR) stent, enabling the successful implantation of a new TAVR valve.

View Article and Find Full Text PDF