Relationship of implant stability and bone density derived from computerized tomography images.

Clin Implant Dent Relat Res

Unit of Periodontology, Department of Oral Health Sciences, University of Leuven, Leuven, Belgium.

Published: February 2018

Background And Purpose: Implant stability is one of the most important factors influencing osseointegration. Using stereolithographical guides for maximizing precision, this study aimed at investigating the relationship between implant stability and bone density derived from computerized tomography analysis.

Materials And Methods: One hundred ninety-five implants were placed in 48 patients using digitally designed stereolithographical surgical guides. Ninety-five implants were placed using a mucosa supported guide and 100 implants were placed using a bone supported guide. Implant stability was measured by means of resonance frequency analysis (RFA) and damping capacity assessment (Periotest, PTV). Bone density (Hounsfield units) was measured at different regions of interest (ROI) and cortex thickness was measured around each implant.

Results: Implant stability correlated significantly with the different ROI. The best correlation for RFA was obtained for the spongious bone ROI (r = .64) and PTV best correlated with the coronal cortex density (r = -.41). Shorter implants (9 mm) had a significantly lower primary stability than longer implants (11, 13, 15 mm). Primary stability was also significantly higher in 4 mm diameter implants than in 3.5 mm diameter implants. A formula for the prediction of primary stability based on the different variables investigated was developed.

Conclusions: Bone density and cortex thickness have a significant influence on implant primary stability. Longer and wider implants reached higher primary stability than shorter and narrower implants. These correlations lose their significance after osseointegration has taken place. Implant stability can be predicted based on an preoperative analysis of bone characteristics.

Download full-text PDF

Source
http://dx.doi.org/10.1111/cid.12579DOI Listing

Publication Analysis

Top Keywords

implant stability
24
primary stability
20
bone density
16
stability
11
implants
9
relationship implant
8
stability bone
8
density derived
8
derived computerized
8
computerized tomography
8

Similar Publications

Enhanced production, functionalization, and applications of polyhydroxyalkanoates from organic waste: A review.

Int J Biol Macromol

January 2025

Department of Chemical and Environmental Engineering and Pro-Vice-Chancellor (Planning & Resources), University of Mauritius, Reduit, Mauritius.

Polyhydroxyalkanoates (PHAs) represent a promising class of biodegradable polyesters synthesized by various microorganisms as energy storage compounds. Their versatility and environmental friendliness make them potential candidates for replacing conventional plastics across numerous applications. However, challenges such as limited mechanical properties, high production costs, and thermal instability have hindered their widespread adoption.

View Article and Find Full Text PDF

Titanium dioxide nanotube arrays (TNTs) generated in situ on the surface of dental implants have been shown to enhance bone integration for load-bearing support while managing load distribution and energy dissipation to prevent bone resorption from overload. However, their inadequate stability limits the clinical use of conventional TNTs. This study introduces an innovative approach to improve the mechanical stability of TNTs while maintaining their bone-integration efficiency.

View Article and Find Full Text PDF

Surveillance of Dual-Mobility Hip Systems: Damage Mode and Clinical Data Analysis.

J Arthroplasty

January 2025

Oakland University William Beaumont School of Medicine, Rochester, MI; Department of Orthopedic Surgery, Corewell Health William Beaumont University Hospital, Royal Oak, MI. Electronic address:

Background: Hip instability following total hip arthroplasty (THA) is among the most common indications for revision surgery. The implantation of dual-mobility (DM) systems, designed to improve stability, continues to rise, and thus, characterizing in vivo implant damage modes is paramount.

Methods: Under an implant retrieval protocol, 51 DM THA systems were analyzed.

View Article and Find Full Text PDF

The effect of bone relaxation on the simulated pull-off force of a cementless femoral knee implant.

J Biomech

January 2025

Radboudumc, Orthopaedic Research Lab, PO Box 9101, 6500 HB Nijmegen, the Netherlands.

Aseptic loosening is the primary cause of revision in cementless total knee arthroplasty (TKA), emphasizing the importance of strong initial stability for long-term implant success. Pre-clinical evaluations are crucial for understanding implant fixation mechanics and improving implant designs. Finite element (FE) analysis models often use linear elastic bone material models, which do not accurately reflect bone's mechanical behavior.

View Article and Find Full Text PDF

Purpose: To evaluate intermediate-term outcomes and complications associated with Ahmed glaucoma valve (AGV) implantation in eyes with type 1 keratoprosthesis (KPro).

Methods: We retrospectively reviewed records of 43 eyes of 43 Indian patients with type 1 KPro and AGV from 2009 to 2021 with a minimum of 6-months of follow-up. Five eyes that had AGV before KPro were excluded, leaving 38 eyes for analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!