Background: Labeled noise reduction (NR) data presented by manufacturers are considered one of the main challenging issues for occupational experts in employing hearing protection devices (HPDs). This study aimed to determine the actual NR data of typical HPDs using the objective fit testing method with a microphone in real ear (MIRE) method.

Methods: Five available commercially earmuff protectors were investigated in 30 workers exposed to reference noise source according to the standard method, ISO 11904-1. Personal attenuation rating (PAR) of the earmuffs was measured based on the MIRE method using a noise dosimeter (SVANTEK, model SV 102).

Results: The results showed that means of PAR of the earmuffs are from 49% to 86% of the nominal NR rating. The PAR values of earmuffs when a typical eyewear was worn differed statistically ( < 0.05). It is revealed that a typical safety eyewear can reduce the mean of the PAR value by approximately 2.5 dB. The results also showed that measurements based on the MIRE method resulted in low variability. The variability in NR values between individuals, within individuals, and within earmuffs was not the statistically significant ( > 0.05).

Conclusion: This study could provide local individual fit data. Ergonomic aspects of the earmuffs and different levels of users experience and awareness can be considered the main factors affecting individual fitting compared with the laboratory condition for acquiring the labeled NR data. Based on the obtained fit testing results, the field application of MIRE can be employed for complementary studies in real workstations while workers perform their regular work duties.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5715487PMC
http://dx.doi.org/10.1016/j.shaw.2017.03.005DOI Listing

Publication Analysis

Top Keywords

fit testing
12
individual fit
8
hearing protection
8
protection devices
8
microphone real
8
real ear
8
considered main
8
rating par
8
par earmuffs
8
based mire
8

Similar Publications

The defoliation quality of mugwort defoliation equipment is an important factor to measure the defoliation efficiency, and the tensile properties of mugwort petiole will have an impact on the defoliation quality, such as the crushing rate and the abscission rate. In order to reduce the crushing rate and improve the abscission rate during mechanical harvesting of mugwort leaves, the tensile properties of mugwort petiole need to be studied. The tensile properties of mugwort petiole are closely related to its macroscopic and microscopic physicochemical parameters.

View Article and Find Full Text PDF

Resilience is central to young children's healthy and happy development. The Child and Youth Resilience Measure (CYRM-R) has been widely used in several countries. However, its construct validity among young children in rural South Africa has not been examined.

View Article and Find Full Text PDF

Background: Variants in the GABRA2 gene, which encodes the α2 subunit of the γ-aminobutyric acid A receptor, have been linked to a rare form of developmental and epileptic encephalopathy (DEE) referred to as DEE78. Only eight patients have been reported globally. This study presents the clinical presentation and genetic analysis of a Chinese family with a child diagnosed with DEE78, due to a novel GABRA2 variant.

View Article and Find Full Text PDF

Background: Cyclic vomiting syndrome (CVS) is defined by its episodic patterning. Furthermore, CVS is associated with other episodic disorders such as migraine and epilepsy. Indeed, many of the medications that are known to be useful for prophylaxis and abortive therapy in CVS are also effective in preventing and aborting migraines and seizures.

View Article and Find Full Text PDF

Aim: To assess recent colonoscopies and CT scans in conjunction with the feacal immunochemical test (FIT) for possibly downgrading urgent suspected cancer (USC) referrals.

Methods:  A retrospective single-centre study was conducted, including all USC referrals for colonoscopy in 2022, excluding anal cancers. The CT and colonoscopy findings for a two-year period prior to the referral, along with the FIT result (if done), were noted.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!