Aims: To assess motion magnitude in different parts of the liver through surgical clips in postoperative patients with hepatocellular carcinoma and to examine the correlation between the clip and diaphragm motion.

Methods: Four-dimensional computed tomography images from 30 liver cancer patients under thermoplastic mask immobilization were selected for this study. Three to seven surgical clips were placed in the resection cavity of each patient. The liver volume on computed tomography image was divided into the right upper (RU), right middle (RM), right lower (RL), hilar, and left lobes. Agreement between the clip and diaphragm motion was assessed by calculating intraclass correlation coefficient, and Bland-Altman analysis (). Furthermore, population-based and patient-specific margins for internal motion were evaluated.

Results: The clips located in the RU lobe showed the largest motion, (7.5±1.6) mm, which was significantly more than in the RM lobe (5.7±2.8 mm, =0.019), RL lobe (4.8±3.3 mm, =0.017), and hilar lobe (4.7±2.7 mm, <0.001) in the cranial-caudal direction. The mean intraclass correlation coefficient values between the clip and diaphragm motion were 0.915, 0.735, 0.678, 0.670, and the mean values between them were 0.1±0.8 mm, 2.3±1.4 mm, 3.1±2.0 mm, 2.4±1.5 mm, when clips were located in the RU lobe, RM lobe, RL lobe, and hilar lobe, respectively. The clip and diaphragm motions had high concordance when clips were located in the RU lobe. Internal margin can be reduced from 5 mm in the cranial-caudal direction based on patient population average and to 3 mm based on patient-specific margins.

Conclusions: The motion magnitude of clips varied significantly depending on their location within the liver. The diaphragm was a more appropriate surrogate for tumor located in the RU lobe than for other lobes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5731437PMC
http://dx.doi.org/10.2147/CMAR.S147185DOI Listing

Publication Analysis

Top Keywords

motion magnitude
8
internal motion
8
postoperative patients
8
patients hepatocellular
8
hepatocellular carcinoma
8
surgical clips
8
clip diaphragm
8
computed tomography
8
motion
6
observation tumor
4

Similar Publications

Taylor's swimming sheet near a soft boundary.

Soft Matter

January 2025

Univ. Bordeaux, CNRS, LOMA, UMR 5798, F-33405 Talence, France.

In 1951, G. I. Taylor modeled swimming microorganisms by hypothesizing an infinite sheet in 2D moving in a viscous medium due to a wave passing through it.

View Article and Find Full Text PDF

Simulated Cam Morphology of the Hip Changes Sacroiliac Motion During Hip Motion and Loading in a Cadaveric Model.

Arthrosc Sports Med Rehabil

December 2024

Department of Orthopedic Surgery and Sports Medicine, Mayo Clinic, Rochester, Minnesota, U.S.A.

Purpose: To determine the relationship between cam morphology of the hip and ipsilateral sacroiliac motion compared to the native hip in a cadaveric model.

Methods: A simulated cam state was created using a 3-dimensional printed cam secured to the head-neck junction of 5 cadaveric hips. Hips were studied using a computed tomography-based optic metrology system and a 6 degree-of-freedom robot to exert an internal rotation torque at 3 different torque levels (6 N-m, 12 N-m, 18 N-m).

View Article and Find Full Text PDF

Progress in understanding the infrared spectrum of the H2O-O2 dimer.

J Chem Phys

January 2025

Department of Physics and Astronomy, University of Calgary, 2500 University Drive North West, Calgary, Alberta T2N 1N4, Canada.

Spectra of the weakly bound H2O-O2 dimer are studied in the region of the H2O ν2 band using a tunable quantum cascade laser to probe a pulsed supersonic slit jet expansion. These are the first gas-phase infrared spectra of H2O-O2 and among only a few such results for O2-containing complexes. Almost 100 infrared lines are assigned based on the ground state combination differences from the microwave spectrum of H2O-O2.

View Article and Find Full Text PDF

Flexible high-deflection strain gauges have been demonstrated to be cost-effective and accessible sensors for capturing human biomechanical deformations. However, the interpretation of these sensors is notably more complex compared to conventional strain gauges, particularly during dynamic motion. In addition to the non-linear viscoelastic behavior of the strain gauge material itself, the dynamic response of the sensors is even more difficult to capture due to spikes in the resistance during strain path changes.

View Article and Find Full Text PDF

Visual perception is characterized by known asymmetries in the visual field; human's visual sensitivity is higher along the horizontal than the vertical meridian, and along the lower than the upper vertical meridian. These asymmetries decrease with decreasing eccentricity from the periphery to the center of gaze, suggesting that they may be absent in the 1-deg foveola, the retinal region used to explore scenes at high-resolution. Using high-precision eyetracking and gaze-contingent display, allowing for accurate control over the stimulated foveolar location despite the continuous eye motion at fixation, we investigated fine visual discrimination at different isoeccentric locations across the foveola and parafovea.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!