Tension-Induced Error Correction and Not Kinetochore Attachment Status Activates the SAC in an Aurora-B/C-Dependent Manner in Oocytes.

Curr Biol

Sorbonne Universités, UPMC Univ. Paris 06, CNRS FRE3631, Institut de Biologie Paris Seine (IBPS), 7 Quai St. Bernard, Paris 75005, France; CNRS UMR7622, Developmental Biology Lab, 7 Quai St. Bernard, 75005 Paris, France. Electronic address:

Published: January 2018

Cell division with partitioning of the genetic material should take place only when paired chromosomes named bivalents (meiosis I) or sister chromatids (mitosis and meiosis II) are correctly attached to the bipolar spindle in a tension-generating manner. For this to happen, the spindle assembly checkpoint (SAC) checks whether unattached kinetochores are present, in which case anaphase onset is delayed to permit further establishment of attachments. Additionally, microtubules are stabilized when they are attached and under tension. In mitosis, attachments not under tension activate the so-named error correction pathway depending on Aurora B kinase substrate phosphorylation. This leads to microtubule detachments, which in turn activates the SAC [1-3]. Meiotic divisions in mammalian oocytes are highly error prone, with severe consequences for fertility and health of the offspring [4, 5]. Correct attachment of chromosomes in meiosis I leads to the generation of stretched bivalents, but-unlike mitosis-not to tension between sister kinetochores, which co-orient. Here, we set out to address whether reduction of tension applied by the spindle on bioriented bivalents activates error correction and, as a consequence, the SAC. Treatment of oocytes in late prometaphase I with Eg5 kinesin inhibitor affects spindle tension, but not attachments, as we show here using an optimized protocol for confocal imaging. After Eg5 inhibition, bivalents are correctly aligned but less stretched, and as a result, Aurora-B/C-dependent error correction with microtubule detachment takes place. This loss of attachments leads to SAC activation. Crucially, SAC activation itself does not require Aurora B/C kinase activity in oocytes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cub.2017.11.049DOI Listing

Publication Analysis

Top Keywords

error correction
16
activates sac
8
sac activation
8
sac
6
tension
5
tension-induced error
4
correction
4
correction kinetochore
4
kinetochore attachment
4
attachment status
4

Similar Publications

Purpose: To investigate the safety and refractive outcomes of neodymium-doped yttrium-aluminum-garnet (Nd:YAG) capsulotomy in pseudophakic eyes with the Light Adjustable Lens (LAL) both before and after completing the light delivery device (LDD) lock-in treatments.

Setting: Private practice in Orange, California, USA.

Design: Retrospective, comparative study.

View Article and Find Full Text PDF

Purpose: We analyzed intraocular lens (IOL) power calculation in a series of patients with a zero diopter power implant. The idea was to bypass the Estimated Lens Plane (ELP), an important variable in normal IOL calculation.

Setting: Large multi-center group practice.

View Article and Find Full Text PDF

Significant changes in pre-dialytic partial pressure of CO (pCO) during a week-long cycle of hemodialysis (HD) can be an effect of the intermittent supplementation of bicarbonate to correct chronic acidosis in patients. Mathematical modeling efforts carried out using the same parameters before each HD session might fail to produce accurate predictions of pCO and plasma bicarbonate concentration (C) because of this variability. A numerical model describing acid-base equilibrium changes during HD was applied to predict pCO, pH, and C in 24 chronic HD patients, using both fixed parameters for the whole week and estimating a new value of minute ventilation (V) and net acid generation rate (G) for each interdialytic interval.

View Article and Find Full Text PDF

Variable power functional dilution adjustment of spot urine.

Sci Rep

January 2025

Praxis Dr.Carmine, Etzelstrasse 21, Pfaeffikon SZ, 8808, Switzerland.

Spot-urinary biomarkers are crucial in medical, epidemiological, and environmental studies, but their variability due to hydration levels requires precise dilution adjustments. Traditional methods, like conventional creatinine correction (CCRC), are limited in compensating for variations in urine concentration, causing substantial inconsistencies, particularly at the extremes of the diuresis spectrum. While restricting the creatinine (CRN) range to 0.

View Article and Find Full Text PDF

Exam protocoling is a significant non-interpretive task burden for radiologists. The purpose of this work was to develop a natural language processing (NLP) artificial intelligence (AI) solution for automated protocoling of standard abdomen and pelvic magnetic resonance imaging (MRI) exams from basic associated order information and patient metadata. This Institutional Review Board exempt retrospective study used de-identified metadata from consecutive adult abdominal and pelvic MRI scans performed at our institution spanning 2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!