A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Revascularization of the anterior cerebral artery by Y-shaped superficial temporal artery interposition graft for the treatment of a de novo aneurysm arising at the site of A3-A3 bypass: technical case report. | LitMetric

The most frequently used option to reconstruct the anterior cerebral artery (ACA) is an ACA-ACA side-to-side anastomosis. The long-term outcome and complications of this technique are unclear. The authors report a case of a de novo aneurysm arising at the site of A3-A3 anastomosis. A 53-year-old woman underwent A3-A3 side-to-side anastomosis for the treatment of a ruptured right A2 dissecting aneurysm. At 44 months after surgery, a de novo aneurysm developed at the site of anastomosis. The aneurysm developed in the front wall of the anastomosis site, and projected to the anterosuperior direction. A computational fluid dynamics (CFD) study showed the localized region with high wall shear stress coincident with the pulsation in the front wall of the anastomosis site, where the aneurysm developed. A Y-shaped superficial temporal artery (STA) interposition graft was used successfully to reconstruct both ACAs, and then the aneurysm was trapped. To the authors' knowledge, this is the first case of a de novo aneurysm that developed at the site of an ACA-ACA side-to-side anastomosis. A CFD study showed that hemodynamic stress might be an underlying cause of the aneurysm formation. A Y-shaped STA interposition graft is a useful option to treat this aneurysm. Long-term follow-up is necessary to detect this rare complication after ACA-ACA anastomosis.

Download full-text PDF

Source
http://dx.doi.org/10.3171/2017.6.JNS17931DOI Listing

Publication Analysis

Top Keywords

novo aneurysm
16
aneurysm developed
16
interposition graft
12
side-to-side anastomosis
12
aneurysm
10
anterior cerebral
8
cerebral artery
8
y-shaped superficial
8
superficial temporal
8
temporal artery
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!