A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Prospect of robotic assistance for fully automated brachytherapy seed placement into skull base: Experimental validation in phantom and cadaver. | LitMetric

Background And Purpose: To investigate the feasibility and accuracy of robot-assisted brachytherapy for skull base tumours.

Material And Methods: A custom robot system was tested on both phantom and cadaveric specimen. Cone beam CT (CBCT) images were transferred to the graphical user interface (GUI) for planning trajectories and the data were sent to the robot control unit. Following registration, the puncture needle was inserted into the target by the robot under navigation guidance, and seeds were implanted. Placement error was instantly displayed on the GUI; the result was verified after postoperative image scanning.

Results: A total of 150 seeds (100 for phantom experiments, 50 for cadaveric studies) were deposited by the robot system. In phantom experiments the mean placement error was 0.57 ± 0.21 mm (measured by the navigation system) vs. 1.41 ± 0.38 mm (measured by image fusion) (p < 0.001); in cadaveric studies the corresponding figures were 0.60 ± 0.30 mm vs. 2.48 ± 0.32 mm (p < 0.001). There was no significant difference for comparison of accuracy test in phantom experiments (p = 0.173) as well as in cadaveric studies (p = 0.354). Accuracy was better in the phantom experiment than in cadaveric studies (p < 0.001).

Conclusions: The performance of robot-assisted skull base brachytherapy is feasible and accurate. Dosimetric coverage will need to be demonstrated in further studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.radonc.2017.11.031DOI Listing

Publication Analysis

Top Keywords

skull base
8
robot system
8
placement error
8
phantom experiments
8
prospect robotic
4
robotic assistance
4
assistance fully
4
fully automated
4
automated brachytherapy
4
brachytherapy seed
4