A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Intraocular Pressure Course During the Femtosecond Laser-Assisted Cataract Surgery in Porcine Cadaver Eyes. | LitMetric

Purpose: Femtosecond laser-assisted cataract surgery (FLACS) is an increasingly common procedure. Most laser systems require corneal applanation and thereby increase intraocular pressure (IOP). The purpose of the present study was to evaluate the IOP changes that occur during the FLACS procedure performed using the Catalys femtosecond laser system.

Methods: IOP was measured by direct cannulation of the vitreous body of porcine cadaver eyes (N = 20). By inserting a second cannula connected to a water column, all the eyes were set to a baseline IOP of 20 mm Hg. The eyes were lifted by custom-made stands to achieve the appropriate height and position under the Catalys system. The standard FLACS procedure was performed using varying fragmentation times to assess the influence of tissue fragmentation times on IOP peaks.

Results: We identified significant IOP elevations from baseline IOP levels during all steps of the FLACS procedure (baseline: 20.28 ± 1.32 mm Hg; vacuum: 34.48 ± 4.21 mm Hg; capture: 47.90 ± 13.02 mm Hg; lock: 48.41 ± 9.04 mm Hg; analysis: 47.15 ± 5.97 mm Hg; capsulotomy: 45.74 ± 6.52 mm Hg; fragmentation: 48.41 ± 6.80 mm Hg; end: 17.81 ± 1.61 mm Hg; all P < 0.001). Furthermore, the tissue fragmentation time had a significant effect on the peak IOP values detected (R = 0.62, P = 0.04, n = 9).

Conclusions: The present study reveals significant IOP increases during FLACS procedures carried out using the Catalys system.

Download full-text PDF

Source
http://dx.doi.org/10.1167/iovs.17-21948DOI Listing

Publication Analysis

Top Keywords

flacs procedure
12
iop
9
intraocular pressure
8
femtosecond laser-assisted
8
laser-assisted cataract
8
cataract surgery
8
porcine cadaver
8
cadaver eyes
8
procedure performed
8
baseline iop
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!