A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Electrically Elicited Quadriceps Muscle Torque: A Comparison of 3 Waveforms. | LitMetric

Study Design A controlled laboratory study, with a single-blind, block-randomization crossover design. Objectives To compare the electrically elicited knee extensor torque produced by 3 clinically available waveforms: 2500-Hz burst-modulated alternating current (BMAC), 1000-Hz BMAC, and 1000-Hz burst-modulated biphasic square-wave pulsed current (BMBPC). Background Neuromuscular electrical stimulation (NMES) is the therapeutic use of electrical current to strengthen muscle. Muscle torque produced by NMES is limited by discomfort. Methods The knee extensor maximal volitional isometric torque (KEMVIT) of 33 able-bodied participants (18 female) was measured and used to normalize the electrically elicited knee extensor torque to produce a percent of KEMVIT (%KEMVIT). Electrically elicited isometric knee extensor torque was measured in response to each of the waveforms at the participants' maximum tolerance. Results The average maximum tolerated stimulation produced 32.0 ± 16.7 %KEMVIT with 2500-Hz BMAC, 38.2 ± 18.4 %KEMVIT with 1000-Hz BMAC, and 42.2 ± 17.1 %KEMVIT with 1000-Hz BMBPC. Tukey honest significant difference (HSD) post hoc testing revealed a statistically significant difference between 2500-Hz BMAC and 1000-Hz BMAC (P = .046), and between 2500-Hz BMAC and 1000-Hz BMBPC (P<.001). No statistically significant difference was found between 1000-Hz BMAC and 1000-Hz BMBPC (P = .267). Conclusion For eliciting maximum knee extensor muscle torque, 1000-Hz BMBPC and 1000-Hz BMAC were similarly effective, and 2500-Hz BMAC was less effective. J Orthop Sports Phys Ther 2018;48(3):217-224. Epub 19 Dec 2017. doi:10.2519/jospt.2018.7601.

Download full-text PDF

Source
http://dx.doi.org/10.2519/jospt.2018.7601DOI Listing

Publication Analysis

Top Keywords

electrically elicited
16
knee extensor
16
bmac 1000-hz
16
extensor torque
12
1000-hz bmac
12
2500-hz bmac
12
muscle torque
8
elicited knee
8
torque produced
8
%kemvit 1000-hz
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!